Inspections for the day of: Friday, May 29, 2020.
Number of inspections: 4
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-03143 BLD-Wall cover5/28/20205/29/20205/29/2020 11:05:33 AMAPASS
Level 5 fur downs at rooms 6th. st. south only ok. Pool room exterior wall insulation ok, 1st. level.
BLD20-00327 BLD-Wall Bracing5/28/20205/29/20205/29/2020 10:13:39 AMAFAIL
screened - Clarence Phone #: ###-####. Provide portal frame construction at garage door opening as shown on approved plans. Remove tyvek for wall bracing inspection. Correction notice posted.
BLD18-03767 BLD-Concrete5/28/20205/29/20205/29/2020 10:10:38 AMAPEND
rebar wall- Rocky *screened* Phone #: ###-####. Ok pendind special inspection.
BLD20-01106 BLD-Framing/Rough-in5/29/20205/29/20205/29/2020 9:23:25 AMAFAIL
Phone #: ###-#### Inspection requested via web by Allen Jones. L brace gabel ends down stairs. Complete lateral bracing on A02 trusses and A03 trusses.- Bracing attached to wrong member. Complete bracong on G0D1 2ply and nail off webs as per engineering.