Inspections for the day of: Wednesday, May 3, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00948 Electrical Rough-In5/3/20065/3/20065/3/2006 4:31:10 PMPCANC
Ground ring - Dave; Phone #: ###-#### Internet Inspection Request from: Ione Coleman nr, for lightning only
ELE06-01530 Final5/2/20065/3/20065/3/2006 4:30:07 PMPNH
Phone #: ###-#### Internet Inspection Request from: Dana Moyer called contr, said to recall
ELE06-01534 Permanent Service5/3/20065/3/20065/3/2006 3:38:49 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook wrong address, told contr to fix and recall
ELE05-04540 Electrical Rough-In5/3/20065/3/20065/3/2006 3:00:48 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook met contr to verify 2' depth of u/g in parking lot. ok to cover u/g
ELE06-01516 Permanent Service5/3/20065/3/20065/3/2006 2:29:13 PMPFAIL
brent; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left corr notice, nec 300.5 direct burial conductors shall be 24" deep or have concrete protection, BCC address shall be posted
ELE06-01531 Permanent Service5/3/20065/3/20065/3/2006 1:36:04 PMPPASS
Rick; Phone #: ###-#### Internet Inspection Request from: Ione Coleman p/s u/g n ok
ELE06-01531 Electrical Rough-In5/3/20065/3/20065/3/2006 1:35:28 PMPPASS
re-inspect - Rick; Phone #: ###-#### Internet Inspection Request from: Ione Coleman corr made, ric ok
ELE06-01030 Rough-In Permanent Service5/3/20065/3/20065/3/2006 1:08:03 PMPPASS
Internet Inspection Request from: Latisha Peltier talked to contr, left survey, nec 725.55 class 2&3 cable shall not be run thru same compartments or raceways as class1 circuits, 362.30 ent shall be strapped within 3' of box
ELE06-01016 Final5/2/20065/3/20065/3/2006 11:53:05 AMAPASS
Trailer Key Taped to Lid of Outside Panel Re-inspection Final Alt Contact ###-####; Phone #: ###-#### Internet Inspection Request from: Cathy Felin called left message, job done, see p/s, ok to final
ELE06-00378 ELE-Aging Inspection5/3/20065/3/20065/3/2006 10:31:31 AM DONE
see final
ELE06-00378 Final5/3/20065/3/20065/3/2006 10:31:10 AMAPASS
looked at sign, ok to final
ELE06-01525 Electrical Rough-In5/2/20065/3/20065/3/2006 10:00:40 AMANR
Darryl H. ; Phone #: ###-#### Internet Inspection Request from: Ione Coleman met contr, told to call for pm
ELE06-01507 Rough-In Permanent Service5/1/20065/3/20065/3/2006 9:34:36 AMAPASS
steve ###-#### ric ok, p/s u/g n ok
ELE05-04010 Permanent Service5/2/20065/3/20065/3/2006 8:50:51 AMAPASS
kelly; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g n ok
ELE06-01531 Electrical Rough-In5/2/20065/3/20065/3/2006 8:29:31 AMAFAIL
Rick; Phone #: ###-#### Internet Inspection Request from: Ione Coleman called contr, left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 314.16 boxes shall be of sufficient size to provide free space for all enclosed conductors (garage lites)