ELE07-00147
| Permanent Service | 5/3/2007 | 5/3/2007 | 5/3/2007 4:30:38 PM | P | NR |
|
|
lauren ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called contr, asked if they talked with bldg dept and they had not. Told them they must find out if the building is all 1 building or more than one. They called and then later the bldg official called 370 and confirmed that the building is one 290,000 sq ft bldg and that the service requested is for a ti of about 20,000 sq ft. 370 told contr that there could only be 1 service to a building.
|
ELE07-01591
| Electrical Rough-In | 5/3/2007 | 5/3/2007 | 5/3/2007 3:39:03 PM | P | PASS |
|
|
Access through left side gate and go in back yard Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ric ok
|
ELE07-01585
| Permanent Service | 5/3/2007 | 5/3/2007 | 5/3/2007 2:43:25 PM | P | PASS |
|
|
p/s o/h rec ok, corrections made
|
ELE07-00599
| Electrical Rough-In | 5/2/2007 | 5/3/2007 | 5/3/2007 1:04:13 PM | P | NH |
|
|
Scheduled by a contractor via Hello! on 5/2/2007 at 5:31:47 PM. Contact: ###-####. called to reschedule for am
|
ELE07-01585
| Permanent Service | 5/3/2007 | 5/3/2007 | 5/3/2007 12:42:48 PM | P | FAIL |
|
|
eric ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called contr, left corr notice, nec 110.26 shall provide space about electrical equipment, BCC service shall be brought up to code, grounding, clearances, etc
|
ELE07-00375
| ELE-Aging Inspection | 5/3/2007 | 5/3/2007 | 5/3/2007 11:56:28 AM | | NR |
|
|
sign not up
|
ELE07-01133
| Final | 5/2/2007 | 5/3/2007 | 5/3/2007 10:35:58 AM | A | PASS |
|
|
Eddie; Phone #: ###-#### Internet Inspection Request from: Andrea Whiteman corrections made, ok to cover clg, ok to final, no card to sign
|
ELE06-03574
| Electrical Rough-In | 5/2/2007 | 5/3/2007 | 5/3/2007 9:52:08 AM | A | PASS |
|
|
rough in of kitchen, any questions call Tate @###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose ric kitchen only ok, said to check on update permit for room count
|
ELE07-01088
| Electrical Rough-In | 5/2/2007 | 5/3/2007 | 5/3/2007 9:08:57 AM | A | PASS |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to cover u/g east side anop
|
ELE07-01536
| Electrical Rough-In | 5/2/2007 | 5/3/2007 | 5/3/2007 8:27:35 AM | A | PASS |
|
|
paul - underground; Phone #: ###-#### Internet Inspection Request from: Victoria Beall u/g ok to cover
|
ELE07-01587
| Electrical Rough-In | 5/2/2007 | 5/3/2007 | 5/3/2007 8:06:00 AM | A | PASS |
|
|
Daryl; Phone #: ###-#### Internet Inspection Request from: Andrea Whiteman ric ok, will call service ltr
|