Inspections for the day of: Friday, May 3, 2019.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01560 Electrical Rough-In5/2/20195/3/20195/3/2019 2:04:42 PMPPASS
Later in the day would be better if that works for you Phone #: ###-#### Inspection requested via web by Kurt Carlson Ok cover kitchen.
ELE19-01169 Final5/2/20195/3/20195/3/2019 12:14:12 PMAPASS
Please call one hour before so we can meet you on site to give access. ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Ok final. 225a buss rating allows 70a breaker to be installed.
ELE19-01493 Electrical Rough-In5/3/20195/3/20195/3/2019 11:58:36 AMPCANC
Underground inspection
Please call Joe when entering whitewater park. This is located near Quinn''s pond Phone #: ###-#### >> Inspection requested via web by Tye Thomas Inspection cancelled from web by: Tye Thomas
ELE19-01427 Electrical Rough-In5/2/20195/3/20195/3/2019 11:30:15 AMAPASS
Request inspection for heated floor cabling. Please contact when in route to the job site. Phone #: ###-#### Inspection requested via web by Cortney Hopper Ok cover flr heat up mstr.
ELE19-01527 Rough-In Permanent Service5/2/20195/3/20195/3/2019 10:51:45 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn p/s u/g n ok
ELE19-01621 Electrical Rough-In5/2/20195/3/20195/3/2019 10:21:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Lanham All items UL listed.
ELE19-01530 Electrical Rough-In5/3/20195/3/20195/3/2019 9:53:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Maes All items UL listed.
ELE19-01612 Permanent Service5/2/20195/3/20195/3/2019 9:12:54 AMAPASS
its located between ashgrove ln and the fence. there is a gate there, I will leave the gate open. if you have any questions please call thanks Phone #: ###-#### Inspection requested via web by Kevin Heideman p/s u/g n ok
ELE19-01612 Conference5/3/20195/3/20195/3/2019 9:12:26 AMADONE
Talked to electrician about possibly needing an equipotential ring around service that will be feeding an irrigation pump. 682.33(A) explains that if a service feeds a pump in or on water, it needs to have a 6' diameter ring placed in ground between 4" and 6". #8 bare or insulated minimum.