ELE07-01925
| Final | 5/30/2007 | 5/30/2007 | 5/30/2007 4:10:14 PM | P | PASS |
|
|
Internet Inspection Request from: Alan Lusk u/g done under other permit, lighting ok, lv not done by elect contr, ok to final
|
ELE07-01908
| Temporary Service | 5/30/2007 | 5/30/2007 | 5/30/2007 3:45:51 PM | P | PASS |
|
|
butch; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, t/s o/h n ok
|
ELE07-00147
| Permanent Service | 5/30/2007 | 5/30/2007 | 5/30/2007 3:04:23 PM | P | PASS |
|
|
loren; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s, n,(rec), o/h, ok per 324, told elect to put on deadfront, and labels
|
ELE07-01946
| Electrical Rough-In | 5/30/2007 | 5/30/2007 | 5/30/2007 2:29:17 PM | P | FAIL |
|
|
brandon ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left corr notice, nec 210.52(A)(1)(2) recpts shall be installed in any wall over 2' and 6' from entry- east side, before beds, 210.52(H) recpt shall be installed in hall over 10', 110.26 shall provide clearance and space in front of panel, 210.70(A)(2)(c) shall provide stair lighting and switching, 334.30 nm cable shall not be stapled on edge(bath), BCC shall repair rept for water softener and dryer-mounting and no taps off dryer ckt
|
ELE07-00198
| Final | 5/30/2007 | 5/30/2007 | 5/30/2007 1:49:44 PM | P | PASS |
|
|
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen corrections made, ok to final
|
ELE07-00197
| Final | 5/30/2007 | 5/30/2007 | 5/30/2007 1:23:56 PM | P | PASS |
|
|
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen corrections made, ok to final
|
ELE07-01763
| Final | 5/29/2007 | 5/30/2007 | 5/30/2007 1:01:23 PM | P | NR |
|
|
pool bonding inspection for late afternoon if possible. Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA called, told contr to call when grid is ready, only about 3 rods down, 1 side of pool, also wrong type inspection request
|
ELE07-00756
| Final | 5/30/2007 | 5/30/2007 | 5/30/2007 12:36:05 PM | P | PASS |
|
|
On-site J-man; Gene - ###-####. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson told elect to strap riser, move phone distribution sys, ok to final
|
ELE07-01930
| Electrical Rough-In | 5/29/2007 | 5/30/2007 | 5/30/2007 11:49:02 AM | A | PASS |
|
|
ed - ###-#### call 1/2 hr prior to insp ric kitchen area ok
|
ELE07-00905
| Final | 5/30/2007 | 5/30/2007 | 5/30/2007 10:38:46 AM | A | PASS |
|
|
Please call for access. If there are any problems or questions please call. Thank you Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ok to final
|
ELE04-00301
| Final | 5/24/2007 | 5/30/2007 | 5/30/2007 9:55:50 AM | A | PASS |
|
|
###-#### - leon met contr, will put on some box covers, add light in mech room, ok to final
|
ELE07-01490
| Final | 5/29/2007 | 5/30/2007 | 5/30/2007 8:53:38 AM | A | PASS |
|
|
pat #12; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to final
|
ELE07-01925
| Final | 5/29/2007 | 5/30/2007 | 5/30/2007 8:32:54 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk called, left message, no u/g seen, no lights found, lv not properly installed- conduit not strapped
|
ELE07-01931
| Electrical Rough-In | 5/29/2007 | 5/30/2007 | 5/30/2007 8:03:29 AM | A | NH |
|
|
ANY QUESTIONS PLEASE CALL SKIP KUBIK. Phone #: ###-#### x0000 Internet Inspection Request from: Sandee Johnson equipment not open, called contr to recall and ask for p/s and so can verify what power for
|