Inspections for the day of: Wednesday, May 30, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01925 Final5/30/20075/30/20075/30/2007 4:10:14 PMPPASS
Internet Inspection Request from: Alan Lusk u/g done under other permit, lighting ok, lv not done by elect contr, ok to final
ELE07-01908 Temporary Service5/30/20075/30/20075/30/2007 3:45:51 PMPPASS
butch; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, t/s o/h n ok
ELE07-00147 Permanent Service5/30/20075/30/20075/30/2007 3:04:23 PMPPASS
loren; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s, n,(rec), o/h, ok per 324, told elect to put on deadfront, and labels
ELE07-01946 Electrical Rough-In5/30/20075/30/20075/30/2007 2:29:17 PMPFAIL
brandon ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left corr notice, nec 210.52(A)(1)(2) recpts shall be installed in any wall over 2' and 6' from entry- east side, before beds, 210.52(H) recpt shall be installed in hall over 10', 110.26 shall provide clearance and space in front of panel, 210.70(A)(2)(c) shall provide stair lighting and switching, 334.30 nm cable shall not be stapled on edge(bath), BCC shall repair rept for water softener and dryer-mounting and no taps off dryer ckt
ELE07-00198 Final5/30/20075/30/20075/30/2007 1:49:44 PMPPASS
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen corrections made, ok to final
ELE07-00197 Final5/30/20075/30/20075/30/2007 1:23:56 PMPPASS
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen corrections made, ok to final
ELE07-01763 Final5/29/20075/30/20075/30/2007 1:01:23 PMPNR
pool bonding inspection for late afternoon if possible. Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA called, told contr to call when grid is ready, only about 3 rods down, 1 side of pool, also wrong type inspection request
ELE07-00756 Final5/30/20075/30/20075/30/2007 12:36:05 PMPPASS
On-site J-man; Gene - ###-####. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson told elect to strap riser, move phone distribution sys, ok to final
ELE07-01930 Electrical Rough-In5/29/20075/30/20075/30/2007 11:49:02 AMAPASS
ed - ###-#### call 1/2 hr prior to insp ric kitchen area ok
ELE07-00905 Final5/30/20075/30/20075/30/2007 10:38:46 AMAPASS
Please call for access. If there are any problems or questions please call. Thank you Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ok to final
ELE04-00301 Final5/24/20075/30/20075/30/2007 9:55:50 AMAPASS
###-#### - leon met contr, will put on some box covers, add light in mech room, ok to final
ELE07-01490 Final5/29/20075/30/20075/30/2007 8:53:38 AMAPASS
pat #12; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to final
ELE07-01925 Final5/29/20075/30/20075/30/2007 8:32:54 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Alan Lusk called, left message, no u/g seen, no lights found, lv not properly installed- conduit not strapped
ELE07-01931 Electrical Rough-In5/29/20075/30/20075/30/2007 8:03:29 AMANH
ANY QUESTIONS PLEASE CALL SKIP KUBIK. Phone #: ###-#### x0000 Internet Inspection Request from: Sandee Johnson equipment not open, called contr to recall and ask for p/s and so can verify what power for