Inspections for the day of: Thursday, May 30, 2013.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00894 Final5/29/20135/30/20135/30/2013 4:09:49 PMPFAIL
brian Phone #: ###-#### NEC 406.8(6) Receptacles installed in wet locations require weather resistant listing, service entrance conduit to unattached shop requires strap
ELE13-01366 Electrical Rough-In5/30/20135/30/20135/30/2013 3:24:00 PMPPASS
rough-in ok cover underground conduits for fiber optic cabling
ELE13-00523 Electrical Rough-In5/30/20135/30/20135/30/2013 2:47:05 PMPPASS
jeremy late if possible Phone #: ###-#### rough-in ok cover garage addition
ELE10-02364 Final5/29/20135/30/20135/30/2013 2:22:00 PMPPASS
Final inspection on remodel Phone #: ###-#### >> Inspection requested via web by Daniel Gamboa final ok
ELE13-00086 Electrical Rough-In5/30/20135/30/20135/30/2013 1:38:27 PMPPASS
Dave. Entry. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy rough-in ok cover front entry walls
ELE13-00498 Electrical Rough-In5/30/20135/30/20135/30/2013 1:22:54 PMPPASS
Contact: Andy Eckhart walls & ceiling rough-in please Phone #: ###-#### >> Inspection requested via web by Deb Gooden rough-in ok cover EMS walls and hard lid
ELE13-00735 Final5/29/20135/30/20135/30/2013 12:51:42 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Kevin Koomler Bonding required of rain gutter down spout that is within 5ft. of edge of pool
ELE12-00137 ELE-Aging Inspection5/30/20135/30/20135/30/2013 11:59:04 AM DONE
still under construction
ELE13-00220 Final5/30/20135/30/20135/30/2013 11:35:46 AMPPASS
heath Phone #: ###-#### final ok
ELE13-01304 Final5/29/20135/30/20135/30/2013 9:32:30 AMAFAIL
Mike Phone #: ###-#### Receptacle within 6ft. of bathroom sink or basin require GFCI protection. need to remove extension cord from lighting display
ELE13-01162 Electrical Rough-In5/29/20135/30/20135/30/2013 9:01:37 AMAPASS
we have to change the ceiling mud rings out in the morning they need to be deeper so a late morning is most preferable if you can swing it thanks Don Phone #: ###-#### >> Inspection requested via web by Don Lustig rough-in ok cover east half
ELE13-01357 Temporary Service5/30/20135/30/20135/30/2013 8:42:40 AMAPASS
t/s u/g n ok
ELE13-01357 Final5/29/20135/30/20135/30/2013 8:33:11 AMACANC
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey
ELE13-01356 Temporary Service5/29/20135/30/20135/30/2013 8:30:04 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey t/s u/g n ok
ELE13-00220 Final5/29/20135/30/20135/30/2013 8:03:27 AMAFAIL
garage code 0243 Phone #: ###-#### >> Inspection requested via web by Joe Thomas Dishwasher not wired main breaker not labeled
ELE13-01348 Electrical Rough-In5/30/20135/30/20135/30/2013 7:58:46 AMACANC
U/g conduit from house to detached garage Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI Inspection cancelled from web by: TOM BICANDI
ELE13-01349 Electrical Rough-In5/30/20135/30/20135/30/2013 7:58:22 AMACANC
U/g conduit from house to detached garage Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI
ELE13-01346 Electrical Rough-In5/30/20135/30/20135/30/2013 7:58:05 AMACANC
U/g conduit from house to detached garage Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI
ELE13-01347 Electrical Rough-In5/30/20135/30/20135/30/2013 7:58:03 AMACANC
U/g conduit from house to detached garage Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI
ELE13-01347 Electrical Rough-In5/30/20135/30/20135/30/2013 7:58:01 AMACANC
U/g conduit from house to detached garage Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI
ELE13-01347 Final5/30/20135/30/20135/30/2013 6:33:29 AMACANC
U/g conduit from house to detached garage Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI
ELE13-01339 Permanent Service5/29/20135/30/20135/29/2013 3:42:11 PMACANC
Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Inspection cancelled from web by: Eric Schroeder