Inspections for the day of: Friday, May 30, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-01376 Final5/30/20145/30/20145/30/2014 2:17:38 PMPCANC
Call Dene with any questions
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser see t/s
ELE14-01376 Temporary Service5/30/20145/30/20145/30/2014 2:17:17 PMPPASS
Call Dene with any questions
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser t/s u/g n ok
ELE14-01372 Temporary Service5/30/20145/30/20145/30/2014 2:15:17 PMPFAIL
Kevin Phone #: ###-#### called, too many violations to write- IPCO requires 6" poles, shall provide panel schedule, shall provide gfci protection per NEC 590 for receptacles, shall not over fill boxes,
ELE14-01382 Final5/30/20145/30/20145/30/2014 12:49:34 PMPPASS
Transfer panel is mounted on exterior of house at service equipment Phone #: ###-#### >> Inspection requested via web by Matthew White ok final
ELE13-00471 Electrical Rough-In5/29/20145/30/20145/30/2014 11:57:12 AMAPART
underground conduit for swimming pool Phone #: ###-#### >> Inspection requested via web by Candi Bahem called, ok cover main runs, but keep 5' open at pool light to verify conduit is buried 18" within 5' of pool per NEC 680.10, will call for inspection next week
ELE14-00894 Final5/29/20145/30/20145/30/2014 11:17:50 AMAPASS
Axtel Phone #: ###-#### ok final
ELE14-01339 Electrical Rough-In5/29/20145/30/20145/30/2014 10:19:47 AMAPASS
Wired new outlets and mounted low volt boxes. Phone #: ###-#### >> Inspection requested via web by Greg Idsinga walls only ok cover
ELE14-01368 Temporary Service5/29/20145/30/20145/30/2014 10:00:17 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE14-01367 Temporary Service5/29/20145/30/20145/30/2014 9:42:29 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE14-01339 Electrical Rough-In5/29/20145/30/20145/30/2014 9:25:19 AMANH
Wired new outlets and mounted low volt boxes. Phone #: ###-#### >> Inspection requested via web by Greg Idsinga called, building locked
ELE14-00765 Final5/29/20145/30/20145/30/2014 9:07:18 AMAPASS
CODE 4224 ANY ? CALL ###-#### Phone #: ###-#### >> Inspection requested via web by Bob Glenn ok final
ELE14-01041 Final5/29/20145/30/20145/30/2014 8:14:26 AMAPASS
>> Inspection requested via web by Rowdy Monroe ok final