ELE19-01897
| Electrical Rough-In | 5/30/2019 | 5/30/2019 | 5/30/2019 2:19:36 PM | P | PASS |
|
|
Stan Phone #: ###-#### No laundry room at this time Kitchen only ok to cover
|
ELE19-01042
| Final | 5/30/2019 | 5/30/2019 | 5/30/2019 2:19:35 PM | P | PASS |
|
|
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE19-01922
| Rough-In Permanent Service | 5/29/2019 | 5/30/2019 | 5/30/2019 1:12:26 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga
|
ELE19-01922
| Electrical Rough-In | 5/30/2019 | 5/30/2019 | 5/30/2019 12:38:36 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga P/S done on 5/29 by 362. Rough in only ok to cover
|
ELE18-01857
| Final | 5/30/2019 | 5/30/2019 | 5/30/2019 12:37:28 PM | P | PASS |
|
|
Partial final Phone #: ###-#### Inspection requested via web by cris flores Final ok
|
ELE19-01694
| Final | 5/29/2019 | 5/30/2019 | 5/30/2019 11:36:05 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Steven Ragan 408.4 Panel shall be labeled. 406.12 Dwelling unit receps shall be tamper resistant.(GFCI's Installed in kitchen)
|
ELE19-01746
| Permanent Service | 5/29/2019 | 5/30/2019 | 5/30/2019 11:26:16 AM | A | FAIL |
|
|
energize service only, go through blue fence gate, UFER on Northside, opposite side of panel Phone #: ###-#### Inspection requested via web by Dale Johnson 110.24A Available fault currecnt shall be posted.
|
ELE19-01972
| Final | 5/29/2019 | 5/30/2019 | 5/30/2019 11:11:20 AM | A | PASS |
|
|
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER final ok
|
ELE19-01972
| Electrical Rough-In | 5/29/2019 | 5/30/2019 | 5/30/2019 11:10:59 AM | A | PASS |
|
|
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER rough in ok
|
ELE19-00758
| Electrical Rough-In | 5/29/2019 | 5/30/2019 | 5/30/2019 10:54:20 AM | A | PASS |
|
|
1 1/2" pool panel ug feeder, extend pool conduits on back wall of sunken kitchen, kitchen boxes ; conduit, pergola lights ; outlets ; ceiling fan, bonding of pergola column brackets and granite countertop brackets near autocover vault Phone #: ###-#### Inspection requested via web by Lars Johnson 300.9 Interiors of raceways ubove grade shall be considered wet location. ( Need to transition from romex to THWN from soffit) Bonding, underground and pergola rough in ok.
|
ELE19-00875
| Final | 5/30/2019 | 5/30/2019 | 5/30/2019 10:20:30 AM | A | PASS |
|
|
GARAGE CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn corrections made final ok
|
ELE19-01968
| Rough-In Permanent Service | 5/29/2019 | 5/30/2019 | 5/30/2019 9:51:35 AM | A | PASS |
|
|
Please contact when done so I can fill in the trench Phone #: ###-#### Inspection requested via web by Thomas wilson UG ok p/s u/g n ok
|
ELE19-01833
| Permanent Service | 5/30/2019 | 5/30/2019 | 5/30/2019 9:27:57 AM | P | PASS |
|
|
Richard- please call for access and closer to noon. Phone #: ###-#### need gye wire kit and need solar labels tranferded for final p/s o/h rec ok
|
ELE19-01883
| Permanent Service | 5/29/2019 | 5/30/2019 | 5/30/2019 9:26:50 AM | A | PASS |
|
|
Reinspection-power off for over one year. Call Ryan for lock box code if needed. ###-#### Phone #: ###-#### Inspection requested via web by Ryan Schaffer p/s u/g rec ok
|
ELE18-04683
| Final | 5/29/2019 | 5/30/2019 | 5/30/2019 9:21:13 AM | A | PASS |
|
|
House is unoccupied, lockbox on front door, coed is 470916 Phone #: ###-#### Inspection requested via web by Troy Cobb Corrections made final ok
|
ELE19-00909
| Final | 5/29/2019 | 5/30/2019 | 5/30/2019 8:32:13 AM | A | FAIL |
|
|
access: 1027 **lockbox on the bike rack outside** Phone #: ###-#### Inspection requested via web by David Nelson 406.12 5 Buisness offices, waiting rooms and corridors shall be tamper resistant. 210.8. Recep next to wash basin in Janitors closet.
|
ELE19-01841
| Final | 5/29/2019 | 5/30/2019 | 5/29/2019 12:55:47 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rob Maes Final ok
|