Inspections for the day of: Tuesday, May 31, 2016.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-03526 Conference5/31/20165/31/20165/31/2016 2:35:07 PMPDONE
Clay// please call before- home is hard to find Phone #: ###-####
Discussed kitchen counter top layout and receptacles that service counter top. Tamper resistant, 2 circuits minimum, floor heat in small basement bath tiled over. Discussed GFCI protection of floor heat and counter receptacles. NM cable secure and support.
ELE15-01617 Electrical Rough-In5/31/20165/31/20165/31/2016 1:49:19 PMPPASS
Underground Phone #: ###-#### Inspection requested via web by Kerri Hamilton
North side from center of building to planter and under sidewalk rough in ok cover.
ELE16-01333 Final5/31/20165/31/20165/31/2016 1:19:44 PMPFAIL
Sorry for the trouble on this one. Please do a final inspection on Suite D. Contact is David Joseph ###-####. Please let me know if there is any trouble getting in. We appreciate you. Phone #: ###-#### Inspection requested via web by Laura Longshaw
230.70(B)- Service disconnecting means shall be as to which unit it feeds. Marked unit C.
250.24(A)(5)- Grounded conductor shall ot be connected to non- current carrying metal parts, to equipment grounding conductor, lor to ground on load side of service disconnecting means.
* Permanent service inspection required.
* X-ray equipment shall be set to check listing of equipment prior to final inspection.
* Correct address shall be on permit.
ELE16-01541 Electrical Rough-In5/27/20165/31/20165/31/2016 11:16:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Eric Schroeder
Basement and kitchen receptacles added to comply with kitchen counter areas. Bedrooms just refed boxes not remodelled. Wires under stairs to be boxed in with framing. Rough in ok cover
ELE16-01689 Electrical Rough-In5/30/20165/31/20165/31/2016 9:58:46 AMAPASS
If you have questions, please call Jared at ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan
Kitchen and master bath rough in ok cover
ELE16-01700 Final5/26/20165/31/20165/31/2016 9:38:26 AMAPASS
Please call so I can get you in.
###-####
Eddy Phone #: ###-#### Inspection requested via web by Eddy Udry Final ok
ELE16-01700 Electrical Rough-In5/31/20165/31/20165/31/2016 9:35:49 AMPPASS
Please call so I can get you in.
###-####
Eddy Phone #: ###-#### Inspection requested via web by Eddy Udry
Rough in ok cover
ELE16-01653 Electrical Rough-In5/27/20165/31/20165/31/2016 9:14:25 AMAPASS
ceiling inspection Phone #: ###-#### Inspection requested via web by JENNY EMEL
3rd floor hall grid rough in ok cover
ELE16-01632 Final5/27/20165/31/20165/31/2016 8:50:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Lori Stout
Final ok
ELE16-01701 Temporary Service5/27/20165/31/20165/31/2016 8:15:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
t/s u/g n ok