Inspections for the day of: Thursday, May 31, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-01205 Final5/31/20185/31/20185/31/2018 3:58:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- flue missing on water heater- need uv protection on line set-
MEC18-02390 Final5/31/20185/31/20185/31/2018 3:34:54 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC18-02350 Final5/31/20185/31/20185/31/2018 3:16:39 PMPPASS
Replacing furnace and AC. Please inspect in the PM. Call on way: Darrius ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace a/c coil co ok
MEC18-02438 Rough-in5/31/20185/31/20185/31/2018 2:39:41 PMPNR
Phone #: ###-#### Inspection requested via web by Devony Bullard- framing incomplete on dryer vent furred out
MEC18-02438 Pressure Test5/31/20185/31/20185/31/2018 2:37:26 PMPPASS
Phone #: ###-#### Inspection requested via web by Devony Bullard- 20lb gas pass
MEC18-02237 Rough-in5/30/20185/31/20185/31/2018 1:44:15 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- coil size does not match manual J- exhaust fans need sealed where galv 90 tie onto fan- dryer vent at ceiling needs notched out farther duct is outside wall/ replace adjustable 90 thats smashed from nail plate- need supply and return install in ceiling master bedroom- relieve hanger pressure on gas pipe in wall behind furnace or reroute so no stress on pipe- gauge wont zero out- left notice front window
MEC18-02237 Pressure Test5/30/20185/31/20185/31/2018 1:37:18 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- gauge doesnt zero out
MEC18-02393 Final5/29/20185/31/20185/31/2018 10:55:00 AMAPASS
Please call Jim when going to job site, ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Tyler Collado- a/c coil co ok
MEC17-04262 Mec-Aging Inspection5/31/20185/31/20185/31/2018 9:40:11 AM PEND
contractor will schedule final inspection per phone call
MEC17-00271 Mec-Aging Inspection5/31/20185/31/20185/31/2018 9:36:48 AM NH
no one home- left notice front door
MEC18-02437 Pressure Test5/31/20185/31/20185/31/2018 9:28:25 AMANH
Gas pressure test for outdoor fireplace on south side of house Phone #: ###-#### Inspection requested via web by Kirk Johns- no one home- rang doorbell
MEC18-02099 Rough-in5/30/20185/31/20185/31/2018 9:14:56 AMAPASS
rough in Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok
MEC18-02099 Pressure Test5/31/20185/31/20185/31/2018 9:14:27 AMAPASS
rough in Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 20lb gas pass
MEC18-02356 Pressure Test5/30/20185/31/20185/31/2018 8:16:38 AMAPART
WE HAD PRESSURE TEST DAY BEFORE FOR GAS LINE WORK AND CLIENTS ARE UPGRADING EXISTING GAS METER AND WE NEED A GREEN STICKER TO VERIFY THAT WE DID INDEED PASS PRESSURE TEST INSPECTION- BRIAN WAS THE INSPECTOR AND SAID TO REQUEST AGAIN AND HE WILL GET BACK OVER AND PLACE TAG ONSITE Phone #: ###-#### Inspection requested via web by Rick Montgomery- i tagged new gas line for pressure test already completed per contractors request yesterday- will final permit out when permit is pulled for water heater