Inspections for the day of: Thursday, May 31, 2018.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-02182 Water Heater Final5/24/20185/31/20185/31/2018 3:35:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Chris Field
PLM18-02246 Water and/or Sewer5/30/20185/31/20185/31/2018 3:09:00 PMPPASS
Late afternoon if possible. Phone #: ###-#### Inspection requested via web by Chris Field
PLM17-02575 Other5/31/20185/31/20185/31/2018 3:03:34 PMPPASS
Backflow installation on sprinkler system Phone #: ###-#### Inspection requested via web by Stewart Galbraith
PLM17-02575 DOC - Permit Finaled5/31/20185/31/20185/31/2018 3:03:23 PMPPASS
PLM18-02153 Water Heater Final5/29/20185/31/20185/31/2018 2:42:35 PMPFAIL
PLEASE CALL KERRY WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by JEREMY LINK.
Install a drip leg on the gas line.
Drill a hole at the low point of the t&p
MIS18-00206 PLM-Conference5/31/20185/31/20185/31/2018 2:08:21 PMPFAIL
per Chad Schendiman-Ele & Plm work being done w/o permits-he said to note tht the home is vacant and the key is above the front door.
Plumbing work being done without a permit. Including relocation of the water heater and piping and water softener rought-in. Several fixtures have been removed.
PLM17-02575 PLM-Aging Inspection5/31/20185/31/20185/31/2018 11:20:17 AM PEND
Spoke to Shannon. She will handle
PLM18-02081 Other5/31/20185/31/20185/31/2018 10:43:13 AMAPEND
Nate-homeowner needs conference with inspector even though he did not pull the permit Phone #: ###-####.
Met with Nate (homeowner and Mike Blessing (plumber). The sewer line in the trench is flat the majority of the run with slight grade to 1/4"/ft from the 100 foot make to the house. There is ensuffecient grade from the street to the house connection. The homeowner states that there is 24" approx. from the saddle to the 45 to horizontal in the street. The excavator walked off the job and will not return. I suggested to the owner, Nate to contact another excavator and work with them on lowering the connection at the sewer tap after a calculation is done to verify that will permit an 1/8" /foot grade.
PLM18-02267 Water and/or Sewer5/30/20185/31/20185/31/2018 9:55:51 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Hollowell
PLM18-02267 DOC - Permit Finaled5/31/20185/31/20185/31/2018 9:55:39 AMPPASS
PLM18-02196 Final5/29/20185/31/20185/31/2018 9:25:37 AMANH
Phone #: ###-#### Inspection requested via web by Mary LaFayette
tagged door
PLM18-01943 Groundwork5/31/20185/31/20185/31/2018 8:45:52 AMPPASS
Mark Phone #: ###-####
PLM18-02184 Water Heater Final5/26/20185/31/20185/29/2018 4:14:23 PMPCANC
contact customer ( Scott Donnelly ) # ###-#### for inspection...thanks, Roy Phone #: ###-#### >> Inspection requested via web by Roy Towers Inspection cancelled from web by: Roy Towers