Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM01-01393 Water and/or Sewer5/3/20015/4/20015/4/2001 12:00:00 AMAPASS
###-####
PLM01-01394 Water and/or Sewer5/3/20015/4/20015/4/2001 12:00:00 AMAPASS
###-####
PLM01-01378 Sprinkler (Final)5/3/20015/4/20015/4/2001 12:00:00 AMAPASS
PLM01-01401 Sprinkler (Final)5/4/20015/4/20015/4/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 05/04/2001 at 10:18:25. Contact: ###-####.
PLM01-01405 Water and/or Sewer5/4/20015/4/20015/4/2001 12:00:00 AMPFAIL
###-#### sewer line pipe not approved piping to be in same trench with water line. need's to be sch. 40 dwv. tie in to existing sewer need's to be a y- forty-five combination not san-tee 5/4/2001 4:12:45 PM
PLM01-00285 Final5/4/20015/4/20015/4/2001 12:00:00 AMPPASS
Scheduled by Inspector: 360 On 5/4/2001 2:49:50 PM