Inspections for the day of: Thursday, May 4, 2006.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04271 ELE-Aging Inspection5/4/20065/4/20065/8/2006 9:00:04 AM DONE
no new signs, nr
ELE05-04207 ELE-Aging Inspection5/4/20065/4/20065/8/2006 8:12:39 AM DONE
see final
ELE05-04622 Final5/4/20065/4/20065/4/2006 4:10:52 PMPPASS
Final inspection on hot tub hook up: Outside in back yard, enter through east gate-No dogs in yard. Owner is Bob Mortensen. Please call Todd Hall with any questions; Phone #: ###-#### Internet Inspection Request from: todd hall corrections made, ok to final
ELE06-00113 Electrical Rough-In5/4/20065/4/20065/4/2006 3:45:58 PMPPART
CONTACT: GREG PACK - CEILING INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy 7th floor ceilings ok to cover anop
ELE06-01461 Final5/4/20065/4/20065/4/2006 3:04:59 PMPPASS
Trailer Space C-3 Traier Key taped to top of outside panel - Alt Contact Phone: Kelly ###-####; Phone #: ###-#### Internet Inspection Request from: Cathy Felin ok to final
ELE06-01461 Permanent Service5/4/20065/4/20065/4/2006 3:04:19 PMPPASS
Trailer Space C-3 Traier Key taped to top of outside panel - Alt Contact Phone: Kelly ###-####; Phone #: ###-#### Internet Inspection Request from: Cathy Felin corr made, p/s o/h n ok
ELE06-01576 Temporary Service5/4/20065/4/20065/4/2006 2:02:49 PMPPASS
kerri - ###-#### t/s o/h n ok
ELE06-01566 Rough-In Permanent Service5/4/20065/4/20065/4/2006 1:23:57 PMPPASS
Please call me if there are any problems or questions thank you -Kevin; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ric ok, p/s u/g n ok
ELE06-01567 Final5/4/20065/4/20065/4/2006 1:23:28 PMPCANC
Please call me if there are any problems or questions thank you-Kevin; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon see rip
ELE06-01567 Rough-In Permanent Service5/4/20065/4/20065/4/2006 1:23:02 PMPPASS
Please call me if there are any problems or questions thank you-Kevin; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ric ok, p/s u/g n ok
ELE06-00594 Final5/3/20065/4/20065/4/2006 11:49:03 AMAPASS
Daryl; Phone #: ###-#### Internet Inspection Request from: Ione Coleman ok to final
ELE06-01206 Final5/3/20065/4/20065/4/2006 10:27:40 AMAPASS
delbert - ###-#### called contr to finish panel schedule, ok to final
ELE06-01516 Permanent Service5/4/20065/4/20065/4/2006 10:02:20 AMPPASS
brent; Phone #: ###-#### corr made, p/s o/h n ok
ELE06-00925 Rough-In Permanent Service5/3/20065/4/20065/4/2006 9:41:57 AMACANC
Tully - ufer service; Phone #: ###-#### Internet Inspection Request from: Ione Coleman wrong permit, see ri on 06-01458
ELE06-01458 Electrical Rough-In5/4/20065/4/20065/4/2006 9:40:56 AMAPASS
ok to backfill gec
ELE06-00833 Final5/3/20065/4/20065/4/2006 8:56:44 AMAFAIL
Ceiling inspection only; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called contr, left corr notice, nec 725.8 cables shall be supported by bldg structure with straps, hangers etc so as to not damage the cable, 725.3(B) abandoned cables shall be removed, 300.11(A) independent support wires shall be supported at both ends, 110.12(A) unused openings shall be closed, 314.23 boxes shall be rigidly and securely supported, 330.30(B) mc cable shall be supported within 12" of box,BCC all make-up shall be done(duct control boxes), no ceilings shall be covered until inspected