Inspections for the day of: Monday, May 5, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-00283 Final5/5/20145/5/20145/5/2014 3:13:03 PMPPASS
Patrick Phone #: ###-#### job complete, final ok
ELE12-02135 ELE-Aging Inspection5/5/20145/5/20145/5/2014 2:30:14 PM DONE
see final
ELE12-02135 Final5/5/20145/5/20145/5/2014 2:29:52 PMPPASS
UL Listed signs, final ok
ELE14-01076 Permanent Service5/5/20145/5/20145/5/2014 1:57:19 PMPPASS
Please call Calvin when you are on your way ###-####. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan p/s u/g rec ok
ELE14-00902 Electrical Rough-In5/5/20145/5/20145/5/2014 1:30:01 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Eddy Udry correction done, rough-in ok cover House and garage
ELE14-00767 Final5/5/20145/5/20145/5/2014 1:00:07 PMPFAIL
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin NEC 210.8(B)(2) All kitchen 15 and 20 ampere 120 volt receptacles require GFCI protection
ELE14-00489 Electrical Rough-In5/5/20145/5/20145/5/2014 12:54:34 PMPPASS
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Rough-in ok cover ceiling of West store front entry.
ELE14-00489 Electrical Rough-In5/5/20145/5/20145/5/2014 12:54:33 PMPFAIL
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Exposed conduits traveling down column in store front entry, broken and internal diameter of the conduit has been reduced. Depth of conduit NEC 300.5
ELE14-00489 Electrical Rough-In5/5/20145/5/20145/5/2014 12:53:17 PMPFAIL
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Exposed PVC conduits in store front entry NEC 352.24 Internal diameter of the conduits have been reduced when relocated. NEC 300.5 Depth of conduits encased in concrete
ELE14-00902 Electrical Rough-In5/2/20145/5/20145/5/2014 9:58:05 AMAFAIL
eddy Phone #: ###-#### NEC 300.4 nail plates. NEC 334.30 stapling. missing mudrings, under stairs and in garage for concrete encased electrode
ELE14-00117 Final5/1/20145/5/20145/5/2014 8:44:46 AMAPASS
Joyce Phone #: ###-#### correction done, final ok
ELE14-00711 Electrical Rough-In5/2/20145/5/20145/5/2014 8:21:55 AMAPASS
cover track bonding and light potting Phone #: ###-#### >> Inspection requested via web by Kevin Koomler rough-in ok cover