Inspections for the day of: Monday, May 6, 2002.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD02-01082 BLD-Final5/3/20025/6/20025/6/2002 12:00:00 AMAFAIL
1. FOOTING FROST PROTECTION - Footings and foundations shall be constructed of masonry, concrete or treated wood and shall extend a minimum of 24 inches below finished grade for frost protection. Footings of concrete and masonry shall be of solid material. Foundations supporting wood shall extend at least 6 inches above the adjacent finish grade. 1994 UBC 1806.1 & Boise City Code 4-02-15 expose to verify depth and size.
BLD02-00225 BLD-Final5/3/20025/6/20025/6/2002 12:00:00 AMAFAIL
1. need plm final

2. no occupance allowed/no access to crawll space
BLD01-00654 BLD-Final5/3/20025/6/20025/6/2002 12:00:00 AMAPART
1. inside units ok for final

2. (Guardrail height) The top of guardrails shall not be less than 42" in height. The top of guardrails for stairways, exclusive of their landings, shall be placed not less than 34" above the nosing of stair treads, measured vertically. (1997 UBC 509.2 and Exception #3)
BLD02-00753 BLD-Framing/Rough-in5/3/20025/6/20025/6/2002 12:00:00 AMAPASS
out of time 05-03-02 need mech permit and approval/ ok to cover walls. per plan. 5/6/2002 10:14:13 AM
BLD01-03160 BLD-Framing/Rough-in5/4/20025/6/20025/6/2002 12:00:00 AMPNR
Scheduled by a contractor via Hello! on 05/04/2002 at 16:44:26. Contact: ###-####.
BLD01-02437 BLD-Wall cover5/6/20025/6/20025/6/2002 12:00:00 AMPPASS
###-#### STEVE
BLD01-03256 BLD-Framing/Rough-in5/6/20025/6/20025/6/2002 12:00:00 AMPPART
fr insp ###-#### -jim double stud girder truss at west wall/ 5/6/2002 2:13:21 PM ok to insulate. 5/6/2002 2:13:39 PM
BLD02-00331 BLD-Framing/Rough-in5/6/20025/6/20025/6/2002 12:00:00 AMPFAIL
1. (Tenant demising walls) In buildings containing tenant spaces with occupancy groups classified as A, B, E, F, M, and S, each tenant space shall be separated from other spaces by a wall having a fire-resistive rating of not less than one hour. The tenant separation wall shall extend from the floor to the underside of the highest adjacent ceiling in either tenant space. If openings are provided, they shall be protected as required by the 1997 UBC for 1-hr fire-resistive corridors. (Boise City Building Code 4-02-14)

2. need ele and fire insp.
BLD01-00942 BLD-Framing/Rough-in5/3/20025/6/20025/6/2002 12:00:00 AMPNR
###-#### TIM ###-#### TIM c/n stands ok to insulate walls only. 5/6/2002 12:49:36 PM
BLD02-00753 BLD-Framing/Rough-in5/3/20025/6/20025/6/2002 12:00:00 AMPCANC
###-#### RICHARD ###-#### ###-#### insp done am from lack of time to do all inspctions on friday pm. RICHARD ###-#### 5/6/2002 12:55:55 PM