ELE10-02297
| Final | 5/6/2011 | 5/6/2011 | 5/6/2011 3:13:04 PM | P | CANC |
|
|
Access 0813 Phone #: ###-#### >> Inspection requested via web by cal crosby called, door taped shut, probably sealed flooring, told to check and recall
|
ELE11-00267
| Final | 5/6/2011 | 5/6/2011 | 5/6/2011 3:04:46 PM | P | PASS |
|
|
Please call jeff if you have any questions thanks. Phone #: ###-#### >> Inspection requested via web by Brandon Blackham ok final
|
ELE11-00911
| Permanent Service | 5/6/2011 | 5/6/2011 | 5/6/2011 2:52:03 PM | P | PASS |
|
|
permitted re-connect, conditional, pending inspection for 5/9/11 AM, p/s o/h rec ok
|
ELE11-00907
| Electrical Rough-In | 5/6/2011 | 5/6/2011 | 5/6/2011 2:10:40 PM | P | PASS |
|
|
Justin Phone #: ###-#### ri ok
|
ELE11-00908
| Electrical Rough-In | 5/6/2011 | 5/6/2011 | 5/6/2011 1:31:54 PM | P | FAIL |
|
|
Neal Phone #: ###-#### called, gave corrections, no broken boxes, stapling, make-up
|
ELE11-00903
| Final | 5/6/2011 | 5/6/2011 | 5/6/2011 12:37:21 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, left correction notice, NEC 110.26 shall provide workspace
|
ELE11-00321
| Electrical Rough-In | 5/5/2011 | 5/6/2011 | 5/6/2011 10:19:50 AM | A | PASS |
|
|
lynn Phone #: ###-#### fat grid ceiling only ok to cover
|
ELE11-00892
| Electrical Rough-In | 5/5/2011 | 5/6/2011 | 5/6/2011 9:58:11 AM | A | PASS |
|
|
wall inspection Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot 2 new walls only ok cover , owner and apprentice no licenses, told to not work
|
ELE08-02423
| Electrical Rough-In | 5/5/2011 | 5/6/2011 | 5/6/2011 9:41:41 AM | A | PASS |
|
|
Jason B3 L4 F unit & B3 L2 Corridor Phone #: ###-#### >> Inspection requested via web by Sean DeLacy ri ok anop, 4th floor, 401, 2nd corridor
|
ELE11-00874
| Permanent Service | 5/5/2011 | 5/6/2011 | 5/6/2011 9:16:19 AM | A | PASS |
|
|
Jay Phone #: ###-#### p/s o/h rec ok
|
ELE11-00898
| Electrical Rough-In | 5/5/2011 | 5/6/2011 | 5/6/2011 8:46:42 AM | A | FAIL |
|
|
daryl Phone #: ###-#### called, left correction notice, NEC 334.30 shall secure nm cable within 12" of boxes, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, BCC shall terminate wiring in boxes
|
ELE11-00899
| Temporary Service | 5/5/2011 | 5/6/2011 | 5/6/2011 8:03:06 AM | A | PASS |
|
|
cal Phone #: ###-#### t/s u/g n ok
|
ELE11-00900
| Temporary Service | 5/5/2011 | 5/6/2011 | 5/6/2011 7:52:50 AM | A | PASS |
|
|
cal Phone #: ###-#### t/s u/g n ok
|