ELE14-00882
| Rough-In Permanent Service | 5/6/2014 | 5/6/2014 | 5/7/2014 3:00:49 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by David Nelson checked with pool builder, their electrical contractor is ISquared, they will have them get city permit, ri ok, p/s u/g n ok
|
ELE14-00570
| Electrical Rough-In | 5/5/2014 | 5/6/2014 | 5/6/2014 2:52:16 PM | P | CANC |
|
|
michael Phone #: ###-#### see conf
|
ELE14-00570
| Conference | 5/6/2014 | 5/6/2014 | 5/6/2014 2:51:36 PM | P | DONE |
|
|
michael Phone #: ###-#### reviewed make-up, outlet spacing, stapling, 1 1/4", circuiting, free length conductor, empty house
|
ELE14-01053
| Final | 5/6/2014 | 5/6/2014 | 5/6/2014 2:04:51 PM | P | PASS |
|
|
Matt. Call prior to heading to the site. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy ok final
|
ELE12-00764
| Final | 5/5/2014 | 5/6/2014 | 5/6/2014 1:04:16 PM | P | CANC |
|
|
Darlene Phone #: ###-#### see ri
|
ELE12-00764
| Electrical Rough-In | 5/6/2014 | 5/6/2014 | 5/6/2014 1:03:35 PM | P | FAIL |
|
|
Darlene Phone #: ###-#### met owner, left correction notice, NEC 300.4(A)(C) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 334.30 nm cable shall be stapled within 12" of box or 314.17(C) 8" if more than 1 cable, 210.52(A) shall install receptacles within 6' of entry and 12' maximum between receptacles, BCC shall not install devices until ri complete so free length of conductor can be inspected
|
ELE14-00780
| Final | 5/5/2014 | 5/6/2014 | 5/6/2014 10:34:06 AM | A | NR |
|
|
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot called, dishwasher and disposal not installed, switch cover missing and loose gfci in womens room , will recall
|
ELE14-00465
| Final | 5/6/2014 | 5/6/2014 | 5/6/2014 9:53:30 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn ok final
|
ELE14-00548
| Final | 5/6/2014 | 5/6/2014 | 5/6/2014 9:31:08 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn called, power to a/c receptacle not on, 2 breakers tripping #16, #18 faulted
|
ELE14-01018
| Electrical Rough-In | 5/5/2014 | 5/6/2014 | 5/6/2014 8:56:21 AM | A | PASS |
|
|
Call ###-#### for access code Phone #: ###-#### >> Inspection requested via web by David Nelson ri ok
|
ELE14-01123
| Rough-In Permanent Service | 5/6/2014 | 5/6/2014 | 5/6/2014 8:16:33 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok
|