BLD02-00844
| BLD-Foundation | 5/3/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 05/03/2002 at 12:30:51. Contact: ###-####. Scheduled by a walls placed with out insp / back fill in place.contractor via Hello! on 05/03/2002 at 12:30:51. Contact: ###-####. 5/7/2002 8:43:12 AM
|
BLD01-02848
| BLD-Energy code compliance | 5/3/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | PART |
|
|
###-#### ###-####west side of 2 hr wall assemblie ok/ 5/7/2002 11:24:35 AM
|
BLD02-00245
| BLD-Energy code compliance | 5/6/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | PASS |
|
|
###-#### JOHN ok for cover, 5/7/2002 8:43:37 AM
|
BLD02-00427
| BLD-Final | 5/6/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | FAIL |
|
|
1. FIRE BLOCKING - In combustible construction fire blocking shall be provided (1) In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10-foot intervals both vertical and horizontal, (2) At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings, (3) In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished, (4) In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials, and (5) at openings between attic spaces and chimney chases for factory-built chimneys. (1997 UBC 708.2.1) Where fire blocks are allowed to be of combustible materials, fireblocking shall consist of 2 inches nominal lumber or two thicknesses of 1-inch nominal lumber with broken lap joints or one thickness of 23/32-inch wood structural panel with joints backed by 23/32-inch wood structural panel. Fire blocks may also be gypsum board, cement fiber board, batts or blankets of mineral or glass fiber, or other approved materials installed in such a manner as to be securely retained in place. (1997 UBC 708.2.2) fur down on living room ceilling provide fire blk. max 10 x 10 spacing.
|
BLD02-00391
| BLD-Final | 5/6/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | FAIL |
|
|
kurt ###-#### fn insulate supply boots to sub-floor/ provide front porch footings to support roof structure atched to the house. 5/7/2002 9:29:21 AM
|
BLD01-03236
| BLD-Other | 5/6/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 05/06/2002 at 17:08:04. Contact: ###-####. called in wrong permit . 5/7/2002 9:52:33 AM
|
BLD01-02848
| BLD-Conference | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | A | FAIL |
|
|
1. (Wall through penetrations that prevent passage of flame & hot gases) Where the penetrating items are steel, ferrous, or copper pipes or steel conduits, the material used to fill the annular space shall prevent the passage of flame and hot gases sufficient to ignite cotton waste when subjected to 1997 UBC Standard 7-1 time-temperature fire conditions under a minimum positive pressure differential of 0.01 inch of water column at the location of the penetration for the time period equivalent to the fire rating of the construction penetrated. (1997 UBC 709.6.1 Exception #2)
2. (Wall membrane penetrations) Membrane penetrations of fire-resistive walls shall comply with 1997 UBC Section 709.6 as required for wall through penetrations. (1997 UBC 709.7)
3. submit fire stopping listing for all trades for insp.
|
BLD01-00964
| BLD-Framing/Rough-in | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | P | PART |
|
|
fire caulking tim ###-#### first tower ok pending mech. 5/7/2002 4:36:38 PM
|
BLD01-00942
| BLD-Framing/Rough-in | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | P | PART |
|
|
fr cover ###-#### tim unuseable space behind tub needs 1 hr ceilling. 5/7/2002 4:37:33 PM
|
BLD02-00427
| BLD-Final | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | P | FAIL |
|
|
###-#### early pmout of time 5/7/2002 5:10:47 PM
|
BLD02-01040
| BLD-Foundation | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | P | FAIL |
|
|
RANDY PAGER # ###-####out of time 5/7/2002 5:11:01 PM
|
BLD02-00225
| BLD-Final | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | P | PASS |
|
|
###-#### final ok 5/7/2002 4:48:11 PM
|
BLD02-00832
| BLD-Framing/Rough-in | 5/7/2002 | 5/7/2002 | 5/7/2002 12:00:00 AM | P | FAIL |
|
|
fr garrett- ###-#### out of time 5/7/2002 5:10:36 PM
|