Inspections for the day of: Tuesday, May 7, 2002.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-01170 Electrical Rough-In5/6/20025/7/20025/7/2002 12:00:00 AMANR
r/i- insp on walls- warren- ###-####
ELE02-01225 Rough-In Permanent Service5/6/20025/7/20025/7/2002 12:00:00 AMAFAIL
###-#### before 10 am please, homeowner has to leave do not cover posted no correction need to meet with owner, I have no idea what he is doing grd boxes #12 and 14 mixed needs to staple romex seal KOs connectors for romex at panel and remove catv cable that passes through panel 5/7/2002 11:54:32 AM
ELE02-00075 Rough-In Permanent Service5/6/20025/7/20025/7/2002 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 05/06/2002 at 13:50:35. Contact: ###-####. cad weld below panels where xformer is on roof 5/7/2002 12:15:59 PM
ELE02-00625 Final5/7/20025/7/20025/7/2002 12:00:00 AMAPASS
ok 5/7/2002 1:39:52 PM
ELE02-01340 Permanent Service5/6/20025/7/20025/7/2002 12:00:00 AMPNH
Scheduled by a contractor via Hello! on 05/06/2002 at 14:30:58. Contact: ###-####. no access called contractor will reschedule 5/7/2002 4:39:02 PM
ELE02-00729 Final5/7/20025/7/20025/7/2002 12:00:00 AMPFAIL
###-#### CHRIS called correction posted $42.00 reinspection fee due 250.148 baseboard heaters,also need connector for cable at baseboard heaters, 300.15 terminate spare MC cable in pantry into a box, and install outside fixturs 5/7/2002 5:13:12 PM
ELE02-00809 Electrical Rough-In5/7/20025/7/20025/7/2002 12:00:00 AMPNR
ceiling insp -don ###-#### no r/i conference only ok some conduit runs have too many bends straping, KOs, support needed for 4, 4sq boxes basement 5/7/2002 4:16:26 PM
ELE02-01344 Final5/7/20025/7/20025/7/2002 12:00:00 AMPFAIL
###-#### ED CELL ###-#### PLEASE CALL IF YOU NEED HIM TO MEET YOU THERE called needs disconnect insight of motors, or controler 300.10 emt conn at 4sq box , and lockout for exhaust fan breaker 5/7/2002 2:56:48 PM
ELE02-01356 Electrical Rough-In5/7/20025/7/20025/7/2002 12:00:00 AMPPART
CONFERENCE ONLY ###-#### BILL conference ok 5/7/2002 3:38:08 PM
ELE02-00152 Electrical Rough-In5/7/20025/7/20025/7/2002 12:00:00 AMPPASS
underground- allison ###-#### u/g for driveway complete ok 5/7/2002 5:45:01 PM