Inspections for the day of: Wednesday, May 7, 2008.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-04413 Electrical Rough-In5/6/20085/7/20085/7/2008 4:02:17 PMPPASS
Cover inspection for bath floor heat mat. Inspection for as late as possible in the afternoon please. Thank you! Phone #: ###-#### Internet Inspection Request from: Adam Staigle ok to cover floor heat in bathroom
ELE08-00283 ELE-Aging Inspection5/7/20085/7/20085/7/2008 3:24:20 PM DONE
called contractor, left message to call back for location and to request his inspection
ELE08-00154 ELE-Aging Inspection5/7/20085/7/20085/7/2008 3:06:28 PM DONE
looked at job, see final
ELE08-00154 Final5/7/20085/7/20085/7/2008 2:22:11 PMPPASS
looked at installation, ok to final
ELE08-00993 Final5/7/20085/7/20085/7/2008 2:17:05 PMPPASS
PAUL Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok to final, signed occupancy card
ELE08-00507 Electrical Rough-In5/6/20085/7/20085/7/2008 1:15:26 PMPPART
larry - partial for bathroom and framed walls Phone #: ###-#### ok to cover walls and hard lids only anop
ELE08-01140 Permanent Service5/6/20085/7/20085/7/2008 10:26:44 AMACANC
Phone #: ###-#### Internet Inspection Request from: Jim Williams see conference
ELE08-01140 Conference5/7/20085/7/20085/7/2008 10:26:20 AMADONE
Phone #: ###-#### Internet Inspection Request from: Jim Williams met contractor, talked about sub-panel clearance requirements and piping interferences for basement panel, rest ok, will recall for p/s
ELE08-01063 Electrical Rough-In5/6/20085/7/20085/7/2008 10:07:00 AMAPASS
reinspection Phone #: ###-#### Internet Inspection Request from: Jari Rivers u/g only ok to cover, corrections made
ELE08-01139 Final5/7/20085/7/20085/7/2008 9:46:43 AMAFAIL
Scheduled by a contractor via Hello! on 5/7/2008 at 6:55:10 AM. Contact: ###-####. called, left correction notice, BCC shall affix job id sticker, NEC 310.8(D) insulated conductors exposed to sunlight shall be listed as being sunlight resistant, 408.8 panel shall be dead-front, 230.66 disconnect shall be marked as suitable for service entrance equipment, NOTE: need to see pump and controller
ELE08-00442 Final5/7/20085/7/20085/7/2008 9:30:39 AMPCANC
contact: Shane Korte Phone #: ###-#### Internet Inspection Request from: Deb Gooden Inspection cancelled from web by: Deb Gooden
ELE08-01092 Electrical Rough-In5/6/20085/7/20085/7/2008 8:56:37 AMAFAIL
This is a swimming pool. The inspection needed is underground. Phone #: ###-#### Internet Inspection Request from: Chris Weimar called contractor, left correction notice, NEC 680.10 underground raceways shall be 18" deep within 5' of inside wall of pool
ELE08-01120 Electrical Rough-In5/6/20085/7/20085/7/2008 8:05:08 AMAPASS
Requesting a wall inspection. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty walls and hard lids only ok to cover