Inspections for the day of: Wednesday, May 7, 2014.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-01707 Final5/6/20145/7/20145/7/2014 4:48:02 PMPPASS
Homeowner will not be home until 4 PM. Please call 30 minutes before inspection. Ray Short ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
MEC14-01747 Final5/6/20145/7/20145/7/2014 3:58:41 PMPPASS
Harold Phone #: ###-#### - 20LB gas pressure pass
MEC14-01325 Pressure Test5/7/20145/7/20145/7/2014 3:39:13 PMPPASS
flue p/t
installer scott t ###-#### >> Inspection requested via web by Dustin Rich - 20LB gas pressure pass, 5LB flue pressure pass.
MEC13-03568 Final5/7/20145/7/20145/7/2014 3:00:08 PMPPASS
MEC14-01420 Final4/30/20145/7/20145/7/2014 2:26:25 PMAPASS
MEET DAN (INSTALLER) FOR ROUGH INSPECTION ON BOTH FIREPLACES, WHICH WILL BE READY AROUND 10 A.M. ACCESS HOLES WILL HAVE BEEN CUT OPEN FOR VIEWING. DAN''S CELL # ###-####...FIREPLACES WILL BE READY FOR FINAL INSPECTION TOO. Phone #: ###-#### >> Inspection requested via web by Mike Almanza
MEC14-01420 Rough-in4/30/20145/7/20145/7/2014 2:26:05 PMAPASS
MEET DAN (INSTALLER) FOR ROUGH INSPECTION ON BOTH FIREPLACES, WHICH WILL BE READY AROUND 10 A.M. ACCESS HOLES WILL HAVE BEEN CUT OPEN FOR VIEWING. DAN''S CELL # ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza
MEC14-01420 Conference4/30/20145/7/20145/7/2014 2:24:33 PMADONE
MEET DAN INSTALLER FOR ROUGH INSPECTION ON BOTH FIREPLACES. ACCESS HOLES HAVE BEEN CUT OPEN FOR VIEWING. Phone #: ###-#### >> Inspection requested via web by Mike Almanza
MEC14-00626 Final5/7/20145/7/20145/7/2014 2:06:41 PMPPASS
Please call ted one hour before heading out so he is set up with the flu test. Thank you Phone #: ###-#### >> Inspection requested via web by MARGIE ROWE
MEC14-00831 Final5/7/20145/7/20145/7/2014 1:45:53 PMPPASS
Will Phone #: ###-####
MEC14-01673 Final5/7/20145/7/20145/7/2014 1:02:23 PMPFAIL
Meet at 1:00 Phone ###-#### Furnace is located in attic. Someone needs to meet me her with a ladder to access the attic.
MEC14-01751 Rough-in5/6/20145/7/20145/7/2014 12:43:07 PMAPASS
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN
MEC14-01751 Pressure Test5/6/20145/7/20145/7/2014 12:41:43 PMAPASS
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN -20LB gas pressure pass, 5LB flue pressure pass.
MEC14-01682 Final5/6/20145/7/20145/7/2014 11:51:59 AMAPASS
AM inspection. Please call Michael at ###-#### OR Bridgette at ###-#### prior to inspection. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
MEC14-00450 Final5/7/20145/7/20145/7/2014 11:21:33 AMPCANC
Please call ted one hour before heading out so he is ready for a flu test. Thank you. Phone #: ###-#### >> Inspection requested via web by MARGIE ROWE Inspection cancelled from web by: Margie Rowe
MEC14-00698 Pressure Test5/6/20145/7/20145/7/2014 9:19:27 AMAPASS
Radiant in garage Phone #: ###-#### >> Inspection requested via web by April Thomas - 100LB hydronic pressure test pass for garage floor heating
MEC14-01673 Final5/6/20145/7/20145/7/2014 9:12:16 AMACANC
AM inspection. Please call Mike prior to inspection at ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette - No access. rescheduled for 1:00 today
MEC14-01667 Rough-in5/7/20145/7/20145/7/2014 8:24:39 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Krista Boss
MEC14-01658 Rough-in5/6/20145/7/20145/7/2014 8:14:46 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Frank Marturello
MEC14-01658 Pressure Test5/6/20145/7/20145/7/2014 8:14:24 AMAPASS
5 lb Pressure test on PVC flue pipe. Phone #: ###-#### >> Inspection requested via web by Frank Marturello - 20LB gas pressure pass, 5Lb flue pass