Inspections for the day of: Thursday, May 7, 2015.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01934 ELE-Aging Inspection5/7/20155/7/20155/7/2015 3:46:23 PM DONE
Still waiting for access
ELE12-02132 ELE-Aging Inspection5/7/20155/7/20155/7/2015 3:45:07 PM DONE
Still under construction
ELE15-01117 Final5/7/20155/7/20155/7/2015 3:42:43 PMPPASS
George Phone #: ###-#### Final ok
ELE15-01346 Permanent Service5/7/20155/7/20155/7/2015 2:44:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Don Conley p/s u/g rec ok
ELE15-00516 Final5/7/20155/7/20155/7/2015 2:19:01 PMPPASS
If you have any questions, please call Calvin. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
ELE14-03110 Final5/7/20155/7/20155/7/2015 1:48:46 PMPFAIL
Call Rader ###-#### for access 30 mins prior Phone #: ###-#### Inspection requested via web by Eric Schroeder 110.3 Receptacle outlet not working upstairs right of furnace.
352.30- PVC conduit shall be secured within 3' of terminations.
408.4- Panel schedule shall be complete.
Verbal notice with contractor
ELE15-01324 Electrical Rough-In5/7/20155/7/20155/7/2015 12:53:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Cyndi Dale Contractor to add 5 rooms to permit. Rough in ok cover
ELE15-01315 Electrical Rough-In5/6/20155/7/20155/7/2015 12:06:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Bryan Atkins 2 offices at south end of building wall rough in ok cover
ELE14-03133 ELE-Request for Extension5/6/20155/7/20155/7/2015 11:10:50 AMAPASS
call with questions - Brad Phone #: ###-#### Extension ok
ELE15-00408 Final5/6/20155/7/20155/7/2015 11:03:25 AMAPASS
Request to re inspect for final- for the AM- we fixed the previous problems.
please call Kyle if questions ###-####
Phone #: ###-#### Inspection requested via web by Shane Lott Final ok
ELE15-00674 Final5/6/20155/7/20155/7/2015 10:29:24 AMAPASS
James is the onsite contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok
ELE15-01015 Electrical Rough-In5/6/20155/7/20155/7/2015 10:06:15 AMAPASS
We are requesting a ceiling rough-in inspection for the Bldg. 2 focus room for tomorrow 5/7/15 during the am. Our onsite contact is Rich @ ###-####.

Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate Focus rooms grid rough in ok cover
ELE15-00754 Final5/6/20155/7/20155/7/2015 9:33:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe Final ok
ELE15-01002 Rough-In Permanent Service5/7/20155/7/20155/7/2015 9:10:03 AMAPASS
Please call kyle Fillion at 7137035 30 mins.before arrival. Inspection requested via web by MIKE HAGERTY Rough in for 2 sub panels A and B. 2 Meters required. p/s u/g n ok
ELE15-00839 Final5/6/20155/7/20155/7/2015 8:35:27 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn 110.3- All outdoor receptacle outlets not working, unable to test.