MEC18-01926
| Final | 5/1/2018 | 5/7/2018 | 5/7/2018 4:02:02 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace gas piping co ok
|
MEC18-01926
| Pressure Test | 5/7/2018 | 5/7/2018 | 5/7/2018 4:01:07 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 5lb flue pass- 20lb gas was passed on earlier inspection but not noted and meter is tagged
|
MEC18-01975
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 3:09:46 PM | P | FAIL |
|
|
Final Inspection on Hood Remodel Phone #: ###-#### Inspection requested via web by Randy Keuhey- missing SS metal on front of hood- called Randy and let him know- airbalance on hood ok- equipment in place- just need this SS installed to final out
|
MEC18-01107
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 2:32:30 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- fireplace final ok
|
MEC18-01106
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 2:32:09 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
|
MEC18-01133
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 2:10:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
|
MEC18-00363
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 1:54:22 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- final on 4 units ok
|
MEC18-00365
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 1:54:00 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- final on 4 units ok
|
MIS18-00109
| MEC-Conference | 5/4/2018 | 5/7/2018 | 5/7/2018 12:58:07 PM | A | PART |
|
|
Rachel Phone #: ###-####- need to onstall 1 drip pan grease catcher on hood- need to install SS strips to cover where SS metal is butted together has a gap- move appliances 6" north and south to maintain clearances to hood- TEMP OCCUPANCY OK- left correction notice with new owner and they will call for inspection when they have items addressed
|
MEC18-01955
| Pressure Test | 5/7/2018 | 5/7/2018 | 5/7/2018 11:32:49 AM | A | PASS |
|
|
LATE AM Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|
MEC18-01955
| Rough-in | 5/7/2018 | 5/7/2018 | 5/7/2018 11:32:29 AM | A | CANC |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I passed on 5-3-18
|
MEC18-01030
| Final | 5/4/2018 | 5/7/2018 | 5/7/2018 11:01:47 AM | A | PASS |
|
|
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final on HVAC and fireplace ok
|
MEC18-00976
| Conference | 5/4/2018 | 5/7/2018 | 5/7/2018 10:05:02 AM | A | PASS |
|
|
Duct Blast at 10am. Gerry ###-#### Phone #: ###-#### Inspection requested via web by Debbie Marino- duct blast test pass
|
MEC17-03918
| Mec-Aging Inspection | 5/7/2018 | 5/7/2018 | 5/7/2018 9:20:16 AM | | DONE |
|
|
|
MEC17-03918
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 9:20:06 AM | A | PASS |
|
|
|
MEC18-01897
| Final | 5/4/2018 | 5/7/2018 | 5/7/2018 9:15:13 AM | A | PASS |
|
|
Repairs completed. Please re-inspect Phone #: ###-#### Inspection requested via web by Jerry Crist- furnace ac coil co ok
|
MEC18-01916
| Rough-in | 5/4/2018 | 5/7/2018 | 5/7/2018 8:42:27 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino- gas gauge wont zero out- need ladder provided to access furnace and coil in atic- 2nd drain needs slope from pan to discharge at house doesnt have grade- b vent needs supported better under platform in attic and need 1/4" per foot rise toward roof looks like its running down hill below platform- left correction notice front window
|
MEC18-01916
| Pressure Test | 5/4/2018 | 5/7/2018 | 5/7/2018 8:39:43 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino- gauge wont zero out
|
MEC18-01962
| Final | 5/4/2018 | 5/7/2018 | 5/7/2018 8:27:56 AM | P | CANC |
|
|
please call our install manager Owen when 30-45 mins in route, he will meet you onsite to pressure up flue for 96% while onsite. 2-4p would work best if possible. Thanks so much Phone #: ###-#### >> Inspection requested via web by Rick Montgomery Inspection cancelled from web by: Rick Montgomery
|
MEC17-03500
| Mec-Aging Inspection | 5/7/2018 | 5/7/2018 | 5/7/2018 8:12:38 AM | | DONE |
|
|
|
MEC17-03500
| DOC - Permit Expired | 5/7/2018 | 5/7/2018 | 5/7/2018 8:12:19 AM | A | PASS |
|
|
no calls
|