PLM17-01381
| PLM-Aging Inspection | 5/7/2018 | 5/7/2018 | 5/10/2018 2:39:55 PM | | PEND |
|
|
Met with the homeowner. She will remove the plastic pan and run the t&p with approved material.
|
PLM17-02469
| PLM-Aging Inspection | 5/7/2018 | 5/7/2018 | 5/8/2018 8:29:05 AM | | PASS |
|
|
|
PLM17-03237
| PLM-Aging Inspection | 5/7/2018 | 5/7/2018 | 5/7/2018 4:03:11 PM | | PASS |
|
|
|
PLM17-03237
| DOC - Permit Finaled | 5/7/2018 | 5/7/2018 | 5/7/2018 4:02:59 PM | P | PASS |
|
|
|
PLM18-00792
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 3:23:19 PM | P | PASS |
|
|
Dan Phone #: ###-####
|
PLM18-01691
| Plumbing Rough-in | 5/4/2018 | 5/7/2018 | 5/7/2018 3:09:34 PM | P | PASS |
|
|
JOB # 19694 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM18-01829
| Water Heater Final | 5/4/2018 | 5/7/2018 | 5/7/2018 2:54:02 PM | P | PASS |
|
|
Jennifer Gruber. Please call Jenn on way, she will inform her mother, who will be onsite. ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
|
PLM17-02407
| Plumbing Rough-in | 5/7/2018 | 5/7/2018 | 5/7/2018 2:54:02 PM | P | PASS |
|
|
JOHNNY IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. Pharmacy sink
|
PLM18-01846
| Final | 5/7/2018 | 5/7/2018 | 5/7/2018 1:49:53 PM | P | PASS |
|
|
Matthew Wright was tech ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
|
PLM18-01773
| Final | 5/2/2018 | 5/7/2018 | 5/7/2018 11:22:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
PLM18-01828
| Water Heater Final | 5/4/2018 | 5/7/2018 | 5/7/2018 11:06:13 AM | A | FAIL |
|
|
Rick Simpson ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart. The hot and cold water lines are crossed at teh water heater. Cold water going into the hot side.
|
PLM18-00781
| Final | 5/5/2018 | 5/7/2018 | 5/7/2018 10:43:19 AM | A | PASS |
|
|
thanks, Pat Phone #: ###-#### Inspection requested via web by pat batten
|
PLM18-01834
| Water Heater Final | 5/4/2018 | 5/7/2018 | 5/7/2018 10:30:40 AM | A | PASS |
|
|
Gail Sorenson ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
|
PLM18-01836
| Final | 5/4/2018 | 5/7/2018 | 5/7/2018 10:14:09 AM | A | FAIL |
|
|
Water main install. Phone #: ###-#### Inspection requested via web by McKenna Haycock. The water line must have 36" of cover from all points outside of the house.
|
PLM18-01835
| Final | 5/4/2018 | 5/7/2018 | 5/7/2018 9:53:11 AM | A | CANC |
|
|
Please call Dustin 30 minutes in advance for access at ###-#### and call Eddie with any questions at ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Lea Briggs. Passed as a groundwork
|
PLM18-01835
| Groundwork | 5/7/2018 | 5/7/2018 | 5/7/2018 9:52:46 AM | A | PASS |
|
|
Please call Dustin 30 minutes in advance for access at ###-#### and call Eddie with any questions at ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Lea Briggs. A trap primer is required.
|
PLM18-01827
| Water Softner Final | 5/4/2018 | 5/7/2018 | 5/7/2018 9:35:12 AM | A | PASS |
|
|
Buddy Newell. Please call with a heads up.###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
|
PLM18-01718
| Plumbing Rough-in | 5/4/2018 | 5/7/2018 | 5/7/2018 9:10:08 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Smith. 1. Failed dwv test. 2. Paint abs vents that are exposed. 3. Drainage hangers are too loose and not supporting the pipe. 4. The water closet has fixtures upstream of other fixtures.
|
PLM17-03236
| PLM-Aging Inspection | 5/7/2018 | 5/7/2018 | 5/7/2018 8:07:56 AM | | PASS |
|
|
|
PLM17-03236
| DOC - Permit Finaled | 5/7/2018 | 5/7/2018 | 5/7/2018 8:07:44 AM | P | PASS |
|
|
|