Inspections for the day of: Wednesday, May 8, 2002.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD02-00287 BLD-Energy code compliance5/6/20025/8/20025/8/2002 12:00:00 AMAFAIL
1. no aproved plan and engineering on site to inspect c/n isued previously. DO NOT COVER WITH OUT REINSP.
BLD00-01969 BLD-Final5/7/20025/8/20025/8/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 05/07/2002 at 10:50:12. Contact: ###-####. FINAL OK 5/8/2002 11:46:06 AM
BLD02-00447 BLD-Final5/7/20025/8/20025/8/2002 12:00:00 AMAFAIL
1. floor joist at utlity rm floor bottom chord and web cut at duct work requirs bearing support.
BLD02-00442 BLD-Framing/Rough-in5/7/20025/8/20025/8/2002 12:00:00 AMAPART
1. provide engineering to justify truss repair on 3 ply over grage and truss kot1 exstention of top chord west of stairway. bo4at trusses above grage require latral bracing at both ends of compretion web.

2. fire blk fire place at ceilling line 2 nd floor above garage.

3. c/n all other idems made ok ok to insulate.
BLD01-03228 BLD-Other5/7/20025/8/20025/8/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 05/07/2002 at 15:01:36. Contact: ###-####.
BLD02-00427 BLD-Final5/7/20025/8/20025/8/2002 12:00:00 AMAPASS
BLD02-00633 BLD-Framing/Rough-in5/8/20025/8/20025/8/2002 12:00:00 AMPNR
1. RISE AND RUN - The rise of steps shall not be less than 4 inches or greater than 8 inches. The run shall not be less than 9 inches as measured horizontally between the vertical planes of the furthermost projection of adjacent treads. The largest tread run within a flight of stairs shall not exceed the smallest by more than 3/8 inch. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (1997 UBC 1003.3.3.3 and Exception #1)
BLD01-03024 BLD-Final5/8/20025/8/20025/8/2002 12:00:00 AMPFAIL
1. (Glass labels) Each light shall bear the manufacturer's label designating the type and thickness of glass. When approved by the building official, labels may be omitted, provided an affidavit is furnished by the glazing contractor certifying that each light is glazed in accordance with approved plans and specifications. (1997 UBC 2402)
BLD01-03026 BLD-Final5/8/20025/8/20025/8/2002 12:00:00 AMPFAIL
tim ###-#### fn door behind recption to be removed per aproved plan. ? is there a ti plan. 5/8/2002 2:52:07 PM
BLD02-00633 BLD-Energy code compliance5/8/20025/8/20025/8/2002 12:00:00 AMPNR
Scheduled by a contractor via Hello! on 05/08/2002 at 10:41:00. Contact: ###-####.
BLD01-03228 BLD-Other5/7/20025/8/20025/8/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 05/07/2002 at 15:02:18. Contact: ###-####. walls toped out si pending. 5/8/2002 4:52:23 PM
BLD01-02991 BLD-Framing/Rough-in5/7/20025/8/20025/8/2002 12:00:00 AMPFAIL
1. (Fire blocks and draft stops) In combustible construction, fireblocking and draftstopping shall be installed to cut off all concealed draft openings (both vertical and horizontal) and shall form an effective barrier between floors, between a top story and a roof or attic space, and shall subdivide attic spaces, concealed roof spaces and floor-ceiling assemblies. The integrity of all fire blocks and draft stops shall be maintanined. (1997 UBC 708.1)

2. all backing for ada bars must be instaled .
BLD02-00514 BLD-Framing/Rough-in5/7/20025/8/20025/8/2002 12:00:00 AMPPASS

###-#### fred