ELE06-01319
| Electrical Rough-In | 5/8/2006 | 5/8/2006 | 5/9/2006 7:28:18 AM | P | FAIL |
|
|
For cover of inerior. I am told the cans are approved.; Phone #: ###-#### Internet Inspection Request from: Justin Yount corr called 314.16 ,314.43, 314.20 outside boxes shall be flush at time of r/i, recess fixtures shall meet energy code and be labeled air tight
|
ELE06-01523
| Permanent Service | 5/8/2006 | 5/8/2006 | 5/8/2006 4:25:54 PM | P | PASS |
|
|
###-#### - tyler p/s o/h rec. ok
|
ELE06-01568
| Electrical Rough-In | 5/8/2006 | 5/8/2006 | 5/8/2006 3:37:29 PM | P | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer u/g ok corr. posted caled 110.26(F)(2) remove phone junk from below p/s, art. 500 group D gas needs rigid and sealoff for pump power and sensors cords
|
ELE05-02819
| Electrical Rough-In | 5/8/2006 | 5/8/2006 | 5/8/2006 2:43:57 PM | P | FAIL |
|
|
JAMES; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. met owner pvc not large enough for wire fill, 300.5T needs 18" deep,, 314.28(A)(3) LB not big enough, 300.4(A)1)&(D) nail plates and 11/4" 334.30,314.17(B) secure nmb and mc within 12" of boxes , 250.53(G) drive grd rods as code states,,352.48 use approved cement for pvc, 250.64(C) no splices in GEC, note complete all wiring and makeup before inspection requested note partial correction only job not ready, told owner if more violations created permit could be voided
|
ELE06-01525
| Permanent Service | 5/5/2006 | 5/8/2006 | 5/8/2006 1:47:28 PM | P | PASS |
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Barbara Moore p/s u/g rec. ok
|
ELE06-01525
| Electrical Rough-In | 5/8/2006 | 5/8/2006 | 5/8/2006 1:47:01 PM | P | PASS |
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Barbara Moore r/i ok
|
ELE06-01553
| Electrical Rough-In | 5/8/2006 | 5/8/2006 | 5/8/2006 1:09:58 PM | P | PART |
|
|
RUMMER floor heat r/i ok for north unit only
|
ELE06-01593
| Electrical Rough-In | 5/8/2006 | 5/8/2006 | 5/8/2006 12:33:35 PM | P | FAIL |
|
|
Can you call me about an hour before due to I have the access into the house. Thank you; Phone #: ###-#### Internet Inspection Request from: Robert Murray corr. met contr. 314.43 no screws in plastic boxes, 314.16 box fill, 334.30/314.17(C) staple romex 8" of boxes, 300.4(A)(1)&(D) nail plates and 11/4", 210.52(B) no lights on SABC
|
ELE05-04573
| Final | 5/5/2006 | 5/8/2006 | 5/8/2006 10:03:31 AM | A | NR |
|
|
rick; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called inspection ok needs access to j tub
|
ELE06-00446
| Final | 5/5/2006 | 5/8/2006 | 5/8/2006 9:25:40 AM | A | FAIL |
|
|
Internet Inspection Request from: Melyne Davis needs to update permit for correct number of rooms called
|
ELE06-00597
| Final | 5/4/2006 | 5/8/2006 | 5/8/2006 9:21:53 AM | A | FAIL |
|
|
Internet Inspection Request from: Melyne Davis permit needs to be updated for correct room count, and house done on t/s permit called
|
ELE05-03766
| Final | 5/5/2006 | 5/8/2006 | 5/8/2006 9:20:38 AM | A | PASS |
|
|
Internet Inspection Request from: Melyne Davis this is the permit for t/s not house
|
ELE06-00685
| Final | 5/5/2006 | 5/8/2006 | 5/8/2006 9:19:44 AM | A | FAIL |
|
|
Internet Inspection Request from: Melyne Davis house checked out needs to update permit for 15 rooms called
|
ELE06-00444
| Final | 5/4/2006 | 5/8/2006 | 5/8/2006 9:18:20 AM | A | NH |
|
|
Internet Inspection Request from: Melyne Davis notice posted called also needs to update permit for correct room count
|
ELE05-03685
| ELE-Aging Inspection | 5/8/2006 | 5/8/2006 | 5/8/2006 8:07:12 AM | | DONE |
|
|
|
ELE05-03685
| Final | 5/8/2006 | 5/8/2006 | 5/8/2006 8:06:57 AM | A | PASS |
|
|
old sign new faces
|
ELE06-01568
| Final | 5/8/2006 | 5/8/2006 | 5/8/2006 7:57:32 AM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer Inspection cancelled from web by: Dana Moyer
|