Inspections for the day of: Monday, May 8, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03391 ELE-Aging Inspection5/8/20065/8/20065/12/2006 3:42:27 PM NR
suc
ELE06-01204 Permanent Service5/8/20065/8/20065/8/2006 4:47:03 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
panel is not weatherproof.
ELE05-03541 Final5/8/20065/8/20065/8/2006 4:02:51 PMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ELE06-00804 Final5/5/20065/8/20065/8/2006 3:22:14 PMPPASS
CONTACT: CASEY WILDE SUITES 108 & 109; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
ELE06-01600 Permanent Service5/8/20065/8/20065/8/2006 2:58:41 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Phil Baker
provide working clearance in front of sub panel in basement.
add A/C unit to permit.
ELE06-01517 Permanent Service5/8/20065/8/20065/8/2006 2:33:58 PMPPART
Scheduled by a contractor via Hello! on 5/8/2006 at 8:02:32 AM. Contact: ###-####.
check water bond on after transfer of power.
P/S U/G R Ok to transfer power over
ELE06-01609 Permanent Service5/8/20065/8/20065/8/2006 2:18:42 PMPFAIL
possible remodel no building permits may need a stop work
###-#### Paul
water pipe electrode not connected and no branch circurit for temp. power.
no building permit attached to this parcel.
posted stop work.
ELE06-01611 Temporary Service5/8/20065/8/20065/8/2006 1:49:42 PMPNR
###-####
no identification on T/S and each one requires a permit.
ELE06-01382 Electrical Rough-In5/8/20065/8/20065/8/2006 1:37:15 PMPPART
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
ok except arch way wire#12 romex damaged and light box not flush.
ELE05-04639 Final5/5/20065/8/20065/8/2006 10:37:42 AMAPASS
CONTACT: MIKE ROBINSON; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
ELE06-00136 Final5/5/20065/8/20065/8/2006 10:02:15 AMAPASS
richard; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ELE05-03703 Electrical Rough-In5/5/20065/8/20065/8/2006 9:42:32 AMAPART
3RD FLOOR PARTIAL ROUGH-IN INSPECTION. CONTACT IS DAVE @ ###-####. THANKS; Phone #: ###-#### Internet Inspection Request from: Steve Syltie
3rd floor ANOP
ELE06-00855 Final5/8/20065/8/20065/8/2006 9:08:57 AMAPASS
Scheduled by a contractor via Hello! on 5/8/2006 at 7:20:13 AM. Contact: ###-####.
ELE05-03524 Final5/8/20065/8/20065/8/2006 8:48:20 AMAFAIL
###-#### Internet Inspection Request from: Bob Glenn
210.52 Dwelling Unit Receptacle Outlets.
(5) Receptacle Outlet Location. Receptacle outlets shall be located above, but not more than 500 mm (20 in.) above, the countertop.

314.20 In Wall or Ceiling.
In walls and ceilings constructed of wood or other combustible surface material, boxes shall be flush with the finished surface or project therefrom. this is on the first floor.