Inspections for the day of: Tuesday, May 8, 2007.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01652 Conference5/8/20075/8/20075/8/2007 3:40:26 PMADONE
kevin ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
ELE07-01650 Conference5/8/20075/8/20075/8/2007 3:39:24 PMADONE
met contr, wrote corr notice to owner saidBCC no violations shall be retained, example: emt, pvs, mc shall be strapped per code, no openings in boxes, boxes shall be mounted, electrical panel not in bathroom, mc shall be hospital grade with redundand grounding in x-ray room, metal boxes shall be grounded, plans shall be complete, u/g shall be under slab, maintain 1 1/4" for holes and cable and pvc
ELE07-00321 Final5/8/20075/8/20075/8/2007 3:33:33 PMPPART
ted; Phone #: ###-#### Internet Inspection Request from: Victoria called contr to put faceplates on in kitchen and do panel schedule then call for final
ELE07-00590 Final5/8/20075/8/20075/8/2007 3:02:49 PMPPASS
robert ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to final
ELE07-00590 Permanent Service5/8/20075/8/20075/8/2007 3:01:16 PMPPASS
robert ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corrections made, p/s o/h n ok
ELE07-01652 Temporary Service5/8/20075/8/20075/8/2007 2:21:05 PMPFAIL
kevin ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called left corr notice, nec 250.24(A) gec shall be connected to grounded conductor at service, 312.5 all conductors entering enclosures shall have abrasion protection
ELE07-01648 Permanent Service5/8/20075/8/20075/8/2007 1:49:44 PMPPASS
brent; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called, left survey, nec 348.30 fmc shall be supported by an approved method within 12" of boxes
ELE07-01638 Conference5/7/20075/8/20075/8/2007 1:30:55 PMPDONE
kaj -- ###-#### call 1st before insp talked with owner about re-modek for house and when to call for inspection, how far to go to bring up to code, small appliance branch ckts, bath and outside ckts, range and dryer 4-wire
ELE07-00570 Conference5/7/20075/8/20075/8/2007 12:40:47 PMPDONE
gayla; Phone #: ###-#### Internet Inspection Request from: Victoria Beall reviewed fittings, 1 1/4", make-up, flush boxes, 6" free conductor, 15a gfci to feed garage
ELE07-01650 Electrical Rough-In5/8/20075/8/20075/8/2007 10:32:50 AMPCANC
dene - call for key location; Phone #: ###-#### Internet Inspection Request from: Victoria Beall see conference
ELE07-01633 Electrical Rough-In5/7/20075/8/20075/8/2007 9:46:37 AMAPASS
jay; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok
ELE07-01551 Electrical Rough-In5/7/20075/8/20075/8/2007 8:59:36 AMACANC
joe - nursury bathroom; Phone #: ###-#### Internet Inspection Request from: Victoria Beall contr called wrong location for inspection
ELE07-01634 Rough-In Permanent Service5/7/20075/8/20075/8/2007 8:46:35 AMAPASS
brandon; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok, p/s u/g n ok
ELE07-01513 Electrical Rough-In5/7/20075/8/20075/8/2007 8:08:30 AMAFAIL
greg - underground pipe ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left message, BCC all u/g shall be inspected before cover. (Raceway from bldg to sign at sw corner property) told bldr needed grade line to be sure 24" depth could be measured.
ELE07-01623 Final5/7/20075/8/20075/7/2007 3:34:44 PMAPASS
gayle ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith see final