Inspections for the day of: Thursday, May 8, 2014.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-01770 Final5/7/20145/8/20145/8/2014 4:14:12 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Brad Allison -20LB GAS PRESSURE PASS
MEC14-01042 Final5/7/20145/8/20145/8/2014 3:48:27 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Dan Otero - NO ACCESS INTO HOUSE UNTIL TOMORROW. THEY JUST DID THE FLOORS TODAY.
MEC14-01628 Rough-in5/7/20145/8/20145/8/2014 3:31:24 PMPPASS
Please contact Chad to corrdinate time and access. Phone #: ###-#### >> Inspection requested via web by Lisa Whitney
MEC14-01651 Rough-in5/8/20145/8/20145/8/2014 3:05:26 PMPPART
cover inspection
Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen - OK TO COVER SOFFITS IN BATHROOMS.
MEC14-00391 Final5/8/20145/8/20145/8/2014 2:29:50 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Karl Hestekin - NEED TO ADD WALL SUPPORTS TO THE VERTICAL SECTION OF STAINLESS STEEL VENT PIPE. NEED TO ADD SUPPORTS TO THE VENT PIPES ON THE ROOF. tHERE IS A NEW CHILLER IMSTALLED ON PRESSURE TREATED RED WOOD ON THE ROOF, CHILLER WAS SUPPLIED BY GENRAL INSTALLED ON THE ROOF BY KMD MECH. DO NOT KNOW IF THIS WAS STRUCTRALY ENGINEERED FOR THE WIEGHT. THE OWNER SAID THE REFRIGIRATION PIPPING WAS DONE BY THE PLUMBER. I CAN;T FIND A PERMIT FOR OT. I TOLD THE OWNER IT NEEDS TO BE PERMITED. NONE OF THE PIPPING WAS INSULATED.
MEC14-01679 Rough-in5/8/20145/8/20145/8/2014 1:48:52 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Gary Reeves - 20LB gas pressure, 5LB flue pressure pass.
MEC14-01771 Pressure Test5/8/20145/8/20145/8/2014 12:57:12 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Amanda Drake -20LB gas pressure pass
MEC14-01744 Rough-in5/7/20145/8/20145/8/2014 11:41:46 AMAPASS
rough Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen
MEC14-01743 Rough-in5/7/20145/8/20145/8/2014 11:40:59 AMAPASS
rough Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen
MEC14-01085 Final5/7/20145/8/20145/8/2014 10:43:09 AMAPASS
Please call James at ###-#### with any questions, thank you. >> Inspection requested via web by 4 Seasons
MEC14-01737 Final5/7/20145/8/20145/8/2014 10:19:08 AMAPASS
This is a Flue Pressure and Final Inspect. Pls meet our installer at home at 10 AM . Install Mgr, Allen, Ph is ###-####. 5LB flue pressure pass

Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
MEC14-00247 Final5/7/20145/8/20145/8/2014 9:50:09 AMAPASS
This is a AM Final inspection. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
MEC14-01494 Final5/7/20145/8/20145/8/2014 9:33:47 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Joe Bertwell
MEC13-04478 Final5/7/20145/8/20145/8/2014 9:15:17 AMAPASS
Please contact Jason with any questions. Phone #: ###-#### >> Inspection requested via web by Lisa Whitney
MEC13-01423 Final5/7/20145/8/20145/8/2014 8:53:12 AMAPASS
Must be there first thing in the morning with a call to Mark ###-####. Thanks Phone #: ###-#### >> Inspection requested via web by Allie Courter
MEC14-01771 Pressure Test5/7/20145/8/20145/8/2014 8:37:36 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Amanda Drake - not holding pressure