Inspections for the day of: Friday, May 8, 2015.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00932 ELE-Aging Inspection5/8/20155/8/20155/15/2015 2:02:41 PM DONE
Job complete
ELE14-03110 Final5/7/20155/8/20155/8/2015 3:15:19 PMAPASS
Please call Rader ###-#### for access 30 mins prior Phone #: ###-#### Inspection requested via web by Eric Schroeder Corrections done
ELE15-00734 Final5/8/20155/8/20155/8/2015 2:52:18 PMPPASS
Phone #: ###-#### Inspection requested via web by Jim Williams Final ok
ELE14-02327 Final5/8/20155/8/20155/8/2015 2:33:08 PMPPASS
Find Alton // Alton Phone #: ###-#### Final ok
ELE15-01341 Final5/8/20155/8/20155/8/2015 2:08:24 PMPPASS
Added four exit/emergency lights. Fished from switches in room and one from crawlspace. The building inspector only required an emergency light downstairs as it is a storage room but we added exit sign as well. Thanks Phone #: ###-#### Inspection requested via web by Mark Hennequin Final ok
ELE15-00294 Final5/8/20155/8/20155/8/2015 1:23:14 PMPPASS
For access please call ED 1/2 hr prior to inspection.###-#### Inspection requested via web by Terry Scott Final ok
ELE15-01101 Electrical Rough-In5/7/20155/8/20155/8/2015 12:57:56 PMPPASS
James Phone #: ###-#### Parapet walls as noted on contractor print rough in ok cover
ELE15-01353 Temporary Service5/7/20155/8/20155/8/2015 10:57:16 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
t/s u/g n ok
ELE07-02082 ELE-Aging Inspection5/8/20155/8/20155/8/2015 10:56:30 AM DONE
Still under construction
ELE15-01350 Electrical Rough-In5/7/20155/8/20155/8/2015 10:27:30 AMAPASS
Von. Wall Cover. Phone #: ###-#### Inspection requested via web by Sean DeLacy Detached building to north of main head quarters. Storage room wall rough in ok cover
ELE14-02819 Final5/8/20155/8/20155/8/2015 9:45:41 AMAFAIL
Phone #: ###-#### Inspection requested via web by kendall bender 358.26- Max number of bends between pull points with EMT shall not exceed 360 degrees. run to fire panel
410.46- Luminaires with exposed metal parts shall have means of connecting equipment grounding conductor. No lug ran thru hole in base
ELE15-00567 Final5/7/20155/8/20155/8/2015 8:23:39 AMAPASS
Call ###-#### for access. Phone #: ###-#### Inspection requested via web by Heath Thomas Final ok