ELE19-01485
| Final | 5/8/2019 | 5/8/2019 | 5/8/2019 3:07:28 PM | P | FAIL |
|
|
PLEAS CALL ONE HOUR BEFORE SO WE CAN MEET YOU ON-SITE: Barry Spencer, electrician: ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Called no return call, went to residence and waited
|
ELE19-01494
| Final | 5/8/2019 | 5/8/2019 | 5/8/2019 2:10:28 PM | P | CANC |
|
|
Final Inspection Contact Alex Ybarra Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek No final at this time
|
ELE19-01494
| Electrical Rough-In | 5/8/2019 | 5/8/2019 | 5/8/2019 2:10:18 PM | P | PASS |
|
|
Final Inspection Contact Alex Ybarra Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Two conduits installed to street light ok to cover
|
ELE19-01327
| Temporary Service | 5/8/2019 | 5/8/2019 | 5/8/2019 1:59:40 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Inspection cancelled from web by: Bryan McLaughlin
|
ELE18-03317
| Electrical Rough-In | 5/8/2019 | 5/8/2019 | 5/8/2019 1:54:26 PM | P | PASS |
|
|
Building G Light Poles Contact Scott Wilson Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Light poles ok to pour
|
ELE19-01638
| Rough-In Permanent Service | 5/7/2019 | 5/8/2019 | 5/8/2019 1:44:55 PM | P | PASS |
|
|
Upgrading service. Looking to re energize for PM reconnection. Thanks Phone #: ###-#### Inspection requested via web by Kelly Felin p/s o/h rec ok
|
ELE19-01176
| Rough-In Permanent Service | 5/7/2019 | 5/8/2019 | 5/8/2019 11:55:11 AM | A | PASS |
|
|
They will be open. If you have any questions please feel free to contact Clay ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Duplex units ok to cover p/s u/g n ok
|
ELE19-01559
| Electrical Rough-In | 5/8/2019 | 5/8/2019 | 5/8/2019 11:32:41 AM | A | FAIL |
|
|
Wall cover for Addition, Still have interior fishing work to do on existing side of structure. Contact Greg ###-#### Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer 334.30 Securing of MN cable shall not be greater then 12" of and clamped box and not more then 8" of a non clamping type boxe.... throughout whole addition
|
ELE19-01665
| Electrical Rough-In | 5/7/2019 | 5/8/2019 | 5/8/2019 11:04:11 AM | A | PASS |
|
|
please call first so i know to be there. this is a partical inspection for in ground conduit thanks Phone #: ###-#### Inspection requested via web by Eddy Udry U/G in serving area and walls behind ok to cover
|
ELE19-01682
| Electrical Rough-In | 5/7/2019 | 5/8/2019 | 5/8/2019 10:42:51 AM | A | PASS |
|
|
call first, Pat, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER Floor heat in hall bath ok to cover
|
ELE19-01111
| Final | 5/7/2019 | 5/8/2019 | 5/8/2019 10:23:42 AM | A | PASS |
|
|
Garage man doors both up and down should be open since both are un-occupied at the present, call me if any issues arise! Thx. Steve Phone #: ###-#### Inspection requested via web by Steven Meredith Final ok
|
ELE18-04438
| Final | 5/7/2019 | 5/8/2019 | 5/8/2019 10:05:41 AM | A | FAIL |
|
|
There I is a hidden key in the entry underneath a 2x12 block Phone #: ###-#### Inspection requested via web by Neal Rumsey 210.52 (e)(1) One and two family dwellings shall have a recetpacle located at front and back(front needs one)
|
ELE19-01556
| Electrical Rough-In | 5/7/2019 | 5/8/2019 | 5/8/2019 9:43:10 AM | A | PASS |
|
|
If possible, notify the number above when headed to the jobsite! Thank you! Phone #: ###-#### Inspection requested via web by BRS Permitting Solar array U/L listing and scope of work ok
|
ELE19-01679
| Electrical Rough-In | 5/7/2019 | 5/8/2019 | 5/8/2019 9:30:29 AM | A | FAIL |
|
|
Justin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Ok to insulate other then back room with no receptacle installed Need smokes installed Fix fan in living room with no insulation in box
|
ELE19-00774
| Final | 5/7/2019 | 5/8/2019 | 5/8/2019 9:10:41 AM | A | PASS |
|
|
the breaker tie down is installed, it is a new style, its a black plastic piece top center of the panel over the main breaker, please call for any questions, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren Corrections fixed final ok
|