ELE02-00679
| Final | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PASS |
|
|
Mark ###-#### ok 5/9/2002 10:50:35 AM
|
ELE02-00729
| Final | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PASS |
|
|
###-#### ok 5/8/2002 5:44:52 PM
|
ELE02-01353
| Final | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 05/08/2002 at 12:05:24. Contact: ###-####. no power see added p/s inspection 5/9/2002 11:36:00 AM
|
ELE02-01298
| Rough-In Permanent Service | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 05/08/2002 at 13:38:39. Contact: ###-####. r/i ok
p/s u/g needs meter set ok 5/9/2002 12:02:30 PM
|
ELE01-04322
| Final | 5/7/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PASS |
|
|
###-#### THERRIN ok 5/9/2002 6:53:56 PM
|
ELE02-01344
| Final | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PASS |
|
|
fn insp- ed -###-#### ok 5/9/2002 12:25:03 PM
|
ELE02-01298
| Final | 5/9/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PART |
|
|
called some units locked will complete final when I do my PM inspection there
|
ELE02-01353
| Permanent Service | 5/9/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | A | PASS |
|
|
p/s u/g new ok
|
ELE02-01344
| Rough-In Permanent Service | 5/9/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | PASS |
|
|
p/s u/g new ok
|
ELE02-01402
| Rough-In Permanent Service | 5/9/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | PART |
|
|
###-#### MIKE RAMSEY there is no p/s
r/i ok for Mbed,and bath, and hall bath 5/9/2002 5:48:11 PM
|
ELE02-01308
| Final | 5/9/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | NR |
|
|
fn insp- chad ###-#### owner does not want anyone on the painted floor till 05/10/02 called 5/9/2002 6:00:58 PM
|
ELE02-00625
| Final | 5/7/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 05/07/2002 at 07:37:34. Contact: ###-####. was done 05/07/02 5/8/2002 6:44:56 PM
|
ELE01-02604
| Final | 5/9/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | FAIL |
|
|
###-#### gary cor. posted called 110.3 (B) needs access too j tub motor, use only manufactrues brand breakers, 300.10 shall not metallic flex with non metallic kit cabinet,210.52(A)(2)#3, 410.8 needs MB closet shelves install so clearences can be checked 5/9/2002 4:07:39 PM
|
ELE01-04321
| Final | 5/7/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | PASS |
|
|
###-#### THERRIN ok 5/10/2002 10:31:58 AM
|
ELE02-01206
| Permanent Service | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | PASS |
|
|
FOR POOL ###-#### BILL
p/s u/g rec. ok 5/9/2002 4:57:25 PM
|
ELE02-01340
| Electrical Rough-In | 5/8/2002 | 5/9/2002 | 5/9/2002 12:00:00 AM | P | PART |
|
|
JERRY ###-#### CONF ONLY met with contractor went over corrections, contractor said the code is stupid 5/9/2002 3:08:04 PM
|