Inspections for the day of: Wednesday, May 9, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00432 ELE-Aging Inspection5/9/20075/9/20075/15/2007 11:41:59 AM DONE
suc
ELE07-01666 Electrical Rough-In5/9/20075/9/20075/9/2007 3:21:44 PMPPASS
Internet Inspection Request from: Shane Vigil ric new addition only ok
ELE07-01654 Temporary Service5/9/20075/9/20075/9/2007 2:49:06 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Joe Thomas corr made, t/s u/g n ok
ELE07-00841 Electrical Rough-In5/8/20075/9/20075/9/2007 2:12:20 PMPPASS
KENNETH ; Phone #: ###-#### Internet Inspection Request from: Darla Downs corr made, ric ok
ELE07-00147 Conference5/9/20075/9/20075/9/2007 1:40:43 PMPDONE
bob x 204; Phone #: ###-#### Internet Inspection Request from: Victoria Beall talked about services and where drops could and could not be since whole area 1 building
ELE07-01114 Electrical Rough-In5/9/20075/9/20075/9/2007 11:57:43 AMPFAIL
Scheduled by a contractor via Hello! on 5/9/2007 at 8:44:49 AM. Contact: ###-####. called left corr notice, nec 680.26 (B) news breif, mesh shall be held off ground 1 1/2" and tied at crosses not to exceed 12"
ELE07-01668 Rough-In Permanent Service5/9/20075/9/20075/9/2007 10:42:54 AMPPASS
please inspect the power ped. that had to be moved due to the road widening and the relocation for power hook-up. Thanks Phone #: ###-#### x0000 Internet Inspection Request from: BRIAN KEITH ri ok, p/s u/g n ok
ELE07-01657 Conference5/8/20075/9/20075/9/2007 10:10:12 AMACANC
Chris this is for a conduet inspection; Phone #: ###-#### Internet Inspection Request from: Darla Downs wrong type request, see ri
ELE07-01657 Electrical Rough-In5/9/20075/9/20075/9/2007 10:09:06 AMAPASS
Chris this is for a conduet inspection; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok to cover u/g house to garage
ELE07-00815 Rough-In Permanent Service5/8/20075/9/20075/9/2007 9:33:21 AMACANC
robert - upstairs; Phone #: ###-#### Internet Inspection Request from: Victoria Beall wrong type request, see ri
ELE07-00815 Electrical Rough-In5/9/20075/9/20075/9/2007 9:32:45 AMAPASS
robert - upstairs; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok main level only
ELE07-01652 Temporary Service5/8/20075/9/20075/9/2007 9:06:40 AMAPASS
kevin; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, t/s oh n ok
ELE07-01586 Conference5/8/20075/9/20075/9/2007 8:37:43 AMADONE
chris; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met elec contr and general, reviewed what needs done, left corr notice to owner nec 110.12(A) unused openings shall be closed, 330.30(A) mc cable shall be secured within 12" of box, 358.30(A) emt shall be secured within 3' of box, 725.3 abandoned cl 2 & 3 cable shall be removed, 300.11(A) cables and raceways shall not be supported on ceiling grid BCC no violations shall be retained