ELE07-00432
| ELE-Aging Inspection | 5/9/2007 | 5/9/2007 | 5/15/2007 11:41:59 AM | | DONE |
|
|
suc
|
ELE07-01666
| Electrical Rough-In | 5/9/2007 | 5/9/2007 | 5/9/2007 3:21:44 PM | P | PASS |
|
|
Internet Inspection Request from: Shane Vigil ric new addition only ok
|
ELE07-01654
| Temporary Service | 5/9/2007 | 5/9/2007 | 5/9/2007 2:49:06 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas corr made, t/s u/g n ok
|
ELE07-00841
| Electrical Rough-In | 5/8/2007 | 5/9/2007 | 5/9/2007 2:12:20 PM | P | PASS |
|
|
KENNETH ; Phone #: ###-#### Internet Inspection Request from: Darla Downs corr made, ric ok
|
ELE07-00147
| Conference | 5/9/2007 | 5/9/2007 | 5/9/2007 1:40:43 PM | P | DONE |
|
|
bob x 204; Phone #: ###-#### Internet Inspection Request from: Victoria Beall talked about services and where drops could and could not be since whole area 1 building
|
ELE07-01114
| Electrical Rough-In | 5/9/2007 | 5/9/2007 | 5/9/2007 11:57:43 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 5/9/2007 at 8:44:49 AM. Contact: ###-####. called left corr notice, nec 680.26 (B) news breif, mesh shall be held off ground 1 1/2" and tied at crosses not to exceed 12"
|
ELE07-01668
| Rough-In Permanent Service | 5/9/2007 | 5/9/2007 | 5/9/2007 10:42:54 AM | P | PASS |
|
|
please inspect the power ped. that had to be moved due to the road widening and the relocation for power hook-up. Thanks Phone #: ###-#### x0000 Internet Inspection Request from: BRIAN KEITH ri ok, p/s u/g n ok
|
ELE07-01657
| Conference | 5/8/2007 | 5/9/2007 | 5/9/2007 10:10:12 AM | A | CANC |
|
|
Chris this is for a conduet inspection; Phone #: ###-#### Internet Inspection Request from: Darla Downs wrong type request, see ri
|
ELE07-01657
| Electrical Rough-In | 5/9/2007 | 5/9/2007 | 5/9/2007 10:09:06 AM | A | PASS |
|
|
Chris this is for a conduet inspection; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok to cover u/g house to garage
|
ELE07-00815
| Rough-In Permanent Service | 5/8/2007 | 5/9/2007 | 5/9/2007 9:33:21 AM | A | CANC |
|
|
robert - upstairs; Phone #: ###-#### Internet Inspection Request from: Victoria Beall wrong type request, see ri
|
ELE07-00815
| Electrical Rough-In | 5/9/2007 | 5/9/2007 | 5/9/2007 9:32:45 AM | A | PASS |
|
|
robert - upstairs; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok main level only
|
ELE07-01652
| Temporary Service | 5/8/2007 | 5/9/2007 | 5/9/2007 9:06:40 AM | A | PASS |
|
|
kevin; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, t/s oh n ok
|
ELE07-01586
| Conference | 5/8/2007 | 5/9/2007 | 5/9/2007 8:37:43 AM | A | DONE |
|
|
chris; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met elec contr and general, reviewed what needs done, left corr notice to owner nec 110.12(A) unused openings shall be closed, 330.30(A) mc cable shall be secured within 12" of box, 358.30(A) emt shall be secured within 3' of box, 725.3 abandoned cl 2 & 3 cable shall be removed, 300.11(A) cables and raceways shall not be supported on ceiling grid BCC no violations shall be retained
|