Inspections for the day of: Friday, May 9, 2008.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD07-03245 BLD-Final5/9/20085/9/20085/9/2008 5:43:02 PMPNR
rick Note: call for access Phone #: ###-####.
needs elec final.
BLD08-00093 BLD-Energy code compliance5/9/20085/9/20085/9/2008 4:01:25 PMPPASS
john Phone #: ###-####
BLD08-00552 BLD-Other5/9/20085/9/20085/9/2008 2:18:32 PMPPASS
steve Note: ceiling Phone #: ###-####
ESC08-00330 Site Preparation5/9/20085/9/20085/9/2008 2:18:17 PMPPASS
BLD08-00811 BLD-Foundation5/9/20085/9/20085/9/2008 2:18:05 PMPPART
steve Phone #: ###-####wip.
BLD08-00657 BLD-Footing5/8/20085/9/20085/9/2008 10:50:49 AMANR
eric Phone #: ###-####. Needs Geo-tech insp and letter. Also needs to resolve esc. issues.
BLD03-01644 BLD-Final5/8/20085/9/20085/9/2008 10:36:35 AMACANC
309-cheynne Phone #: ###-####. Rescheduled for Monday in am.
BLD07-02455 BLD-Framing/Rough-in5/8/20085/9/20085/9/2008 10:19:48 AMAPART
rob Phone #: ###-####. Ok to rock hardlids at 1st floor ceiling. 1hr. assemblies for exit corridor enclosure has many issues. Noted unprotected openings in ceiling assembly, wall assembly and additional conduit that penetrates exit corridor and does not serve corridor. Also requested UL approved assembly for floor/ceiling assembly at 1hr. corridor, 1st. floor. told contractor not to proceed in this area.