Inspections for the day of: Friday, May 9, 2014.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-00625 Final5/9/20145/9/20145/9/2014 4:43:39 PMPFAIL
Please call Margie at ###-#### one hour before the inspection so she can set up flue test. Thank you. >> Inspection requested via web by MARGIE ROWE - 5LB FLUE PRESSURE FAIL, NEED TO SLEEVE THE UPPER COMBUSTION AIR TO ABOVE THE INSULATION LEVEL.
MEC14-01578 Final5/8/20145/9/20145/9/2014 3:52:40 PMPPASS
Homeowner Jen Harkness and Mark Nagel phone ###-#### >> Inspection requested via web by Mary LaFayette
MEC14-01552 Final5/9/20145/9/20145/9/2014 3:52:20 PMPPASS
request after 4 - manny Phone #: ###-####
MEC14-01675 Rough-in5/8/20145/9/20145/9/2014 3:27:25 PMPPART
R/I and pressure test-Richard Phone #: ###-#### - 1ST LAYOR DUCT WRAP OK. NEED 18" CLEARANCE TO COMBUSTABLE FROM HOOD, TEMPRATURE DIFFERENTIAL BETWEEN MAKE UP AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10DEG., MAKE UP AIR NEEDS TO BE INTERLOCKED WITH HOOD, NEED TO PIPE THE DRAIN ON THE SWAP COOLER AWAY FROM ELECTRICAL BOX
MEC14-01676 Final5/8/20145/9/20145/9/2014 2:56:40 PMPFAIL
Please call homeowner, Dustin and Megan Hines at ###-#### or ###-####, prior to inspection. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette -NEED TO DO A PRESSURE TEST ON PVC FLUE, NEED TO PROVIDE CO2 SENSORS
MEC14-01791 Pressure Test5/9/20145/9/20145/9/2014 2:31:34 PMPPASS
Jody Phone #: ###-#### - 20LB GAS PRESSURE PASS
MEC14-01673 Final5/8/20145/9/20145/9/2014 2:17:04 PMPPASS
Our installer will meet you at home at 2:00 PM with a ladder so you can inspect furnace.
Allen, install mgr phone # ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
MEC14-01799 Final5/9/20145/9/20145/9/2014 1:47:58 PMPPASS
please call ahead for access 30min - Cody Phone #: ###-####
MEC14-00982 Final5/8/20145/9/20145/9/2014 12:56:56 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Dan Otero
MEC14-01042 Final5/9/20145/9/20145/9/2014 12:18:53 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Dan Otero
MEC14-01785 Final5/8/20145/9/20145/9/2014 11:27:54 AMAPASS
Contact homeowner for access at ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by Amanda Drake
MEC13-01181 Final5/9/20145/9/20145/9/2014 10:40:46 AMAPASS
please call ###-####
MEC14-01480 Final5/8/20145/9/20145/9/2014 9:59:00 AMAPASS
Gary Phone #: ###-#### -NO CARD ON SITE TO SIGN.
MEC14-01788 Pressure Test5/8/20145/9/20145/9/2014 9:29:29 AMAPASS
Phone #: ###-#### >> Inspection requested via web by anthony allen -20LB gas pressure pass
GCM14-00101 GCM-Rough-in5/8/20145/9/20145/9/2014 8:50:00 AMAPASS
Brian ###-#### Re-inspect
MEC14-01785 Conference5/8/20145/9/20145/8/2014 3:26:26 PMACANC
Contact homeowner for access at ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by Amanda Drake Inspection cancelled from web by: Amanda Drake