Inspections for the day of: Tuesday, June 1, 2004.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-01591 Rough-In Permanent Service5/28/20046/1/20046/1/2004 12:00:00 AMAPASS
###-#### john r/i ok p/s u/g new ok 6/1/2004 9:59:50 AM
ELE04-01591 Electrical Rough-In5/28/20046/1/20046/1/2004 12:00:00 AMADONE
###-#### john
ELE04-00710 Final5/31/20046/1/20046/1/2004 12:00:00 AMAPART
Phone #: ###-#### Internet Inspection Request from: Steve Craig T/O ok card signed 6/1/2004 9:18:51 AM
ELE04-00710 Final5/31/20046/1/20046/1/2004 12:00:00 AMAPART
Phone #: ###-#### Internet Inspection Request from: Steve Craig T/O ok card signed 6/1/2004 9:18:01 AM
ELE04-01597 Electrical Rough-In6/1/20046/1/20046/1/2004 12:00:00 AMPPART
###-#### bob underground pipe inspect from house too garage ok 6/1/2004 4:35:18 PM
ELE04-00844 Electrical Rough-In6/1/20046/1/20046/1/2004 12:00:00 AMPPART
Brian -- please call first, thanks.; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes conference ok 6/1/2004 4:01:02 PM
ELE04-01581 Electrical Rough-In6/1/20046/1/20046/1/2004 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 6/1/2004 at 8:52:19 AM. partial bond and r/i pool light u/g only 6/1/2004 2:24:36 PM
ELE04-01379 Final6/1/20046/1/20046/1/2004 12:00:00 AMPPASS
contact: Shane Korte; Phone #: ###-#### Internet Inspection Request from: Deb McCoy ok no card at job site 6/1/2004 2:58:43 PM
ELE04-01183 Final6/1/20046/1/20046/1/2004 12:00:00 AMPFAIL
Dan; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes needs neutral kit for disconnect used as sevice equip, uncover trench, needs #8 or larger GEC at pole sevice terminate grd and neutral toether at pole service, sign company needs permit, and shall meet NEC 600.(5)(C)(3)&410.15(B)(2) 6/1/2004 1:18:46 PM
ELE04-01587 Final6/1/20046/1/20046/1/2004 12:00:00 AMPCANC
PLEASE CALL TO MAKE SURE WE ARE READY IT IS A SERVICE CHANGE SO PLEASE COME LATE IN THE AFTERNOON THANKS; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen see added p/s no final some issues with old violations 6/1/2004 4:34:24 PM
ELE04-01605 Electrical Rough-In6/1/20046/1/20046/1/2004 12:00:00 AMPFAIL
###-#### Steve cor. posted called left message 300.14 short equip grds all locations, 314.20 boxes shall be flush with finish sheer walls, 300.4 11/4", 110.14 loose grds crimp sleeves, might need more some detectors? 6/1/2004 2:05:52 PM
ELE04-01587 Permanent Service6/1/20046/1/20046/1/2004 12:00:00 AMPPASS
p/s o/h rec. ok