Inspections for the day of: Wednesday, June 1, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01976 ELE-Aging Inspection6/1/20166/1/20166/3/2016 2:40:05 PM CANC
ELE16-01732 Electrical Rough-In5/31/20166/1/20166/2/2016 8:21:13 AMAFAIL
There should be someone there. If you have any questions, please call Jared at ###-####, thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan
314.23- Boxes shall be secured. 2 boxes in master bed and bath hanging on wire.
314.29- All boxes shall be accessible. Box to left of fireplace appears to have no access when rocked.
ELE13-00256 Final5/31/20166/1/20166/1/2016 2:42:00 PMPFAIL
Ryan Phone #: ###-####
210.8- All receptacles installed in residential garage shall have GFCI protection.
300.4- Where NM cable is ran through bored holes, Holes shall be 1 1/4" from each framing surface. Center holes in studs.
334.30- NM cable shall be secured with in 12" of boxes and panel.
406.12- All receptacle outlets installed in a residential garage shall be tamper resistant type.
ELE13-00256 Permanent Service6/1/20166/1/20166/1/2016 2:35:19 PMPFAIL
Ryan Phone #: ###-####
250.28- Main bonding jumper shall be installed to ground grounded conductor.
ELE13-01291 Electrical Rough-In6/1/20166/1/20166/1/2016 2:17:47 PMPPASS
Contact Brandon for water fountain bonding. Phone #: ###-#### Inspection requested via web by Tony Keen
Large fountain perimeter bond rough in ok cover
ELE16-01706 Electrical Rough-In5/27/20166/1/20166/1/2016 12:03:29 PMAPASS
Mike// please call 1hr before Phone #: ###-####
Went over HVAC control and boiler controls. Floors 2 and 3 on line. Rough in ok cover
ELE16-01333 Final5/31/20166/1/20166/1/2016 11:20:31 AMAFAIL
Hi Rock,
Address and corrections have been made. Final inspection please. Contact is David Joseph ###-####. Please call if you have any questions as David will not be on the job site or you can call the office ###-####. Phone #: ###-#### Inspection requested via web by Laura Longshaw
Wiring from disconnecting means to x-ray equipment shall be inspected and listing shall be checked.
110.26- Disconnect shall have 30" wide and 36" deep minimum work space in front.
-Dedicated electrical space shall be provided from floor to ceiling width and depth of fused electrical disconnect.
ELE16-01333 Permanent Service5/31/20166/1/20166/1/2016 10:46:08 AMAPASS
Hi Rock,
Permanent Service final inspection please. David Joseph in your contact ###-####. Please call if you have any questions as he will not be on the job site. You can also call the office if you have any questions ###-####.
Thank you for everything and have an awesome day. Phone #: ###-#### Inspection requested via web by Laura Longshaw
2nd meter for space D. p/s u/g n ok
ELE16-01731 Temporary Service5/31/20166/1/20166/1/2016 9:45:17 AMAPASS
Phone #: ###-#### Inspection requested via web by Eric Brown
t/s o/h n ok
ELE13-01291 Electrical Rough-In5/31/20166/1/20166/1/2016 9:29:32 AMAPASS
inspection on water feature bonding Phone #: ###-#### Inspection requested via web by Brandon Robinson
2 smaller fountains perimeter bonds rough in ok cover
ELE16-01155 Final6/1/20166/1/20166/1/2016 9:07:26 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn
Final ok
ESC16-00375 Random Inspection6/1/20166/1/20166/1/2016 9:06:21 AMPPASS
Trash contained, clean job site, OK
ESC16-00281 General Inspection6/1/20166/1/20166/1/2016 9:05:30 AMPPASS
Job site clean trash contained. OK
ELE16-01153 Final6/1/20166/1/20166/1/2016 8:43:49 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE16-01134 Electrical Rough-In6/1/20166/1/20166/1/2016 12:00:00 AMAPASS
We are requesting a rough-in inspection for stairway 3 for this afternoon. Our contact is Tony @ ###-#### or Bobby @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
Discussed required perimeter bond of pool on upper floor. 2nd floor stair 3 walls rough in ok cover