ELE03-00281
| ELE-Aging Inspection | 6/10/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | | PART |
|
|
|
ELE03-01279
| Rough-In Permanent Service | 6/9/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 6/9/2003 at 7:56:53 AM. Contact: ###-####. u/g for p/s and in east end new building 6/10/2003 9:58:18 AM
|
ELE03-00943
| Final | 6/9/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | A | PASS |
|
|
alan; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok 6/10/2003 10:23:43 AM
|
ELE03-01684
| Rough-In Permanent Service | 6/9/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | A | PASS |
|
|
ALAN; Phone #: ###-#### Internet Inspection Request from: Darla Downs r/i ok
p/s u/g new ok 6/10/2003 11:08:42 AM
|
ELE02-03160
| Electrical Rough-In | 6/9/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 6/9/2003 at 12:28:58 PM. Contact: ###-####. u/g ok and 01 ok 6/10/2003 9:09:23 AM
|
ELE03-01681
| Rough-In Permanent Service | 6/9/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | P | FAIL |
|
|
###-#### zane cor. posted called left message 210.52(A) needs recepts bo pocket doors, 250.148 grd all metal boxes, 334.30 shall not staple flat cables on edge, 250.24 (A) terminate G E C at neutral bus 6/10/2003 3:14:29 PM
|
ELE03-01631
| Final | 6/10/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 6/10/2003 at 7:48:46 AM. Contact: ###-####. ok 6/10/2003 4:47:59 PM
|
ELE03-01540
| Electrical Rough-In | 6/10/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 6/10/2003 at 8:07:54 AM. Contact: ###-####. walls up, and down stairs plus ceiling down, u/g for spa ok 6/10/2003 2:00:27 PM
|
ELE03-01555
| Final | 6/10/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | P | PASS |
|
|
henry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok 6/10/2003 2:32:15 PM
|
ELE03-00460
| Electrical Rough-In | 6/10/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | P | PART |
|
|
dennis pole lights; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok 6/10/2003 3:59:37 PM
|
ELE03-01688
| Electrical Rough-In | 6/10/2003 | 6/10/2003 | 6/10/2003 12:00:00 AM | P | PART |
|
|
paul underground; Phone #: ###-#### Internet Inspection Request from: Barbara Moore u/g from garage,shp too house ok 6/10/2003 1:17:07 PM
|