ELE04-01627
| Rough-In Permanent Service | 6/7/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | A | FAIL |
|
|
We hard-wired his sprinkler clock into an existing receptacle in the dining room. Customer requests that you give them a 20 minute heads-up call before you arrive:###-####. Thanks!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell cor. posted called 314.3 shall install bond bushing ,or use non metallic conduit at time clock, 314.16 box fill (old box), 210.19 shall not use #14 to tap form #12(pig tial to recept) 250.148 is box grounded ? (old box) 6/10/2004 9:59:18 AM
|
ELE04-01686
| Temporary Service | 6/9/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | A | PASS |
|
|
re-insp ###-#### -allen t/s u/g new ok 6/10/2004 8:23:16 AM
|
ELE04-01711
| Rough-In Permanent Service | 6/9/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | A | CANC |
|
|
###-#### alan see added p/s 6/10/2004 9:08:43 AM
|
ELE04-01711
| Electrical Rough-In | 6/9/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | A | FAIL |
|
|
alan ###-#### cor. posted called 314.17(C) replace 2,3,4 gang boxes with broken and removed clamps 6/10/2004 9:09:53 AM
|
ELE04-01711
| Permanent Service | 6/10/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | A | PASS |
|
|
p/s u/g new ok
|
ELE03-02683
| Final | 6/10/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | P | PART |
|
|
Contact Tom Betty; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong 90 % ok 6/10/2004 3:08:54 PM
|
ELE04-01409
| Electrical Rough-In | 6/10/2004 | 6/10/2004 | 6/10/2004 12:00:00 AM | P | PASS |
|
|
phil; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ceiling ok 6/10/2004 4:28:44 PM
|