ELE05-02027
| Temporary Service | 6/10/2005 | 6/10/2005 | 6/10/2005 3:46:25 PM | P | PASS |
|
|
MOVED GRND. TO NEUTRAL BUS IN METER AS PER REQUIREMENT.; Phone #: ###-#### Internet Inspection Request from: dennis mcneely t/s u/g new ok
|
ELE05-00963
| Final | 6/10/2005 | 6/10/2005 | 6/10/2005 2:52:39 PM | P | FAIL |
|
|
brian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa cor. posted called correct reversed polarity fam rm right of bedrm door, 210.52(A) shall provide required outlet spacing where closet was removed after r/i inspection in fam rm N E corner
|
ELE05-01969
| Temporary Service | 6/9/2005 | 6/10/2005 | 6/10/2005 2:15:08 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 6/9/2005 at 9:51:20 AM. Contact: ###-####. t/s u/g new ok
|
ELE05-00711
| Final | 6/10/2005 | 6/10/2005 | 6/10/2005 2:05:09 PM | P | PASS |
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie final ok
|
ELE05-02048
| Permanent Service | 6/10/2005 | 6/10/2005 | 6/10/2005 1:31:00 PM | P | PASS |
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s u/g new ok
|
ELE05-02047
| Electrical Rough-In | 6/9/2005 | 6/10/2005 | 6/10/2005 12:34:43 PM | A | FAIL |
|
|
Please meet with Scott or Chuck (####-####) They will show you the new machine and any other work that needs inspected. Thank you.; Phone #:###-#### Internet Inspection Request from: BRIAN KEITH cor. posted called 314.23(H)(1) shall use boxes with hubs for pendant boxes, 110.2 equip shall be listed, 250.97 shall use bond bushing where concentric, eecentric KOs and encounted for bonding over 250 volts to grd, 408.4 label all circuits at panels and switchboards
|
ELE05-00459
| Final | 6/9/2005 | 6/10/2005 | 6/10/2005 10:31:52 AM | A | PASS |
|
|
henry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok corrections made
|
ELE04-02398
| Final | 6/9/2005 | 6/10/2005 | 6/10/2005 8:54:12 AM | A | FAIL |
|
|
mark; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa cor. posted met owner 210.8 needs working gdci in M bath, needs inuse cover outside, and owner needs electrical contractor to secure permit and wire hot tub, or remove all wiring owner installed when he wire hot tub
|
ELE05-02048
| Electrical Rough-In | 6/10/2005 | 6/10/2005 | 6/10/2005 12:00:00 AM | P | FAIL |
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa cor. posted called u/g for parking lot lights covered before inspection
|