Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02617 ELE-Aging Inspection6/10/20136/10/20136/10/2013 4:22:05 PM DONE
waiting on owner
ELE12-01710 Electrical Rough-In6/10/20136/10/20136/10/2013 4:01:17 PMPPASS
Contact: Wes Powell - wall rough-in please Phone #: ###-#### >> Inspection requested via web by Deb Gooden
North stairs floors 15&16, Floor 16 bathrooms rough in ok cover
ESC13-00527 Site Preparation6/10/20136/10/20136/10/2013 2:52:22 PM PASS
Sign posted, demo contained
ELE13-00250 Final6/10/20136/10/20136/10/2013 2:30:33 PMPFAIL
Key Code 3636 Phone #: ###-#### >> Inspection requested via web by cal crosby
408.4- Circuit directory- Label garage circuit in meter main.
110.22(A)- Identification of disconnecting means- identify garage disconnect switch and ac disconnects.
440.12(A)- Overcurrent device shall be sized to the name plate rating. 20a on a 15a max ac.
342.30(A)- Service mast shall be secured with in 3' of meter base.
Wrong number given on ispection request.
ELE13-00388 Final6/10/20136/10/20136/10/2013 1:24:47 PMPPASS
Call Shane before arriving and he will meet you there. Thank you. Phone #: ###-#### >> Inspection requested via web by Eric Brown
Final ok
ELE13-01440 Permanent Service6/10/20136/10/20136/10/2013 12:41:01 PMPCANC
George Phone #: ###-#### needed temp service
ELE13-01440 Temporary Service6/10/20136/10/20136/10/2013 12:40:35 PMPPASS
George Phone #: ###-#### t/s u/g n ok
ELE13-01442 Temporary Service6/8/20136/10/20136/10/2013 12:11:38 PMAPASS
Phone #: ###-#### >> Inspection requested via web by mike brown
t/s u/g n ok
ESC13-00538 Site Preparation6/10/20136/10/20136/10/2013 10:37:20 AM PASS
No activity
ELE13-01431 Electrical Rough-In6/7/20136/10/20136/10/2013 10:32:44 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot
Kitchen refer wall and stair wall rough in ok cover
ELE12-03075 Conference6/10/20136/10/20136/10/2013 10:21:47 AMACANC
2 upstairs bath floor heat Phone #: ###-#### >> Inspection requested via web by Darrin Bybee Needed rough in insp.
ELE12-03075 Electrical Rough-In6/10/20136/10/20136/10/2013 10:21:30 AMPPASS
2 upstairs bath floor heat Phone #: ###-#### >> Inspection requested via web by Darrin Bybee Master bath floor heat rough in ok cover
ELE13-01134 Final6/10/20136/10/20136/10/2013 9:49:37 AMANH
PLEASE CALL AT LEAST 1/2 HOUR BEFORE ARRIVING AT JOB SITE. Phone #: ###-#### >> Inspection requested via web by PAUL PINNEY Locked no access
ELE12-02148 Electrical Rough-In6/10/20136/10/20136/10/2013 9:31:12 AMAPASS
ground work on the gazebo and ground rods for the sub panel . all pipes will be coverd with 4 inchs of concret Phone #: ###-#### >> Inspection requested via web by Erick Baker
Underground and service grounding rough in ok cover
ELE13-01438 Final6/10/20136/10/20136/10/2013 8:46:44 AMPPASS
Final ok
ELE13-01446 Final6/10/20136/10/20136/10/2013 12:00:00 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Mike Cole