Inspections for the day of: Friday, June 10, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00998 ELE-Aging Inspection6/10/20166/10/20166/10/2016 2:54:21 PM CANC
too busy
ELE16-00797 Final6/10/20166/10/20166/10/2016 2:53:58 PMPPASS
Access code 5050+enter Phone #: ###-#### Inspection requested via web by HZ ZAHIC Final ok
ELE15-01348 Electrical Rough-In6/9/20166/10/20166/10/2016 2:20:22 PMPNH
annex level 1 wall inspection Phone #: ###-#### Inspection requested via web by Brandon Robinson
Called 3 times no answer left message, waited 10 minutes, told to recall Monday
ELE16-01845 Electrical Rough-In6/9/20166/10/20166/10/2016 1:56:46 PMPPASS
house empty code 7576, call Jason with any questions ( ###-#### Phone #: ###-#### Inspection requested via web by Dan Rohl
Kitchen remodel rough in ok cover
ELE16-01787 Rough-In Permanent Service6/9/20166/10/20166/10/2016 1:16:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok
ELE16-01835 Temporary Service6/10/20166/10/20166/10/2016 12:11:42 PMAFAIL
Jake Westenskow is electrician on site Phone #: ###-#### Inspection requested via web by Kevin Perez
400.5- SOOW 10-4 flexible cord max overcurrent rating 25 amps, 50 amp installed.
590.6- All power other than 120 volt for receptacles shall have GFCI protection.
ELE16-01152 Final6/9/20166/10/20166/10/2016 11:36:49 AMAPASS
code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE16-00413 Final6/10/20166/10/20166/10/2016 11:19:43 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon
Final ok
ELE16-01653 Electrical Rough-In6/9/20166/10/20166/10/2016 10:12:27 AMAPASS
2nd floor lobby partial ceiling inspection Phone #: ###-#### Inspection requested via web by JENNY EMEL
2nd floor corridor perimeter soffit rough in ok cover
ELE16-01450 Final6/9/20166/10/20166/10/2016 10:03:18 AMAFAIL
I may not have phone service where I am working tomorrow. The interior tenant meter is on order. Looking for an occupancy at this time if you can not do final. Thank you Phone #: ###-#### Inspection requested via web by Cindie Swaim
Unable to grant occupancy, cover on meter base shall be durable, cardboard insufficient protection from accidental contact.
ELE16-01016 Final6/9/20166/10/20166/10/2016 9:08:17 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe Final ok
ELE16-01850 Temporary Service6/9/20166/10/20166/10/2016 8:27:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Hidajet Zahic
t/s u/g n ok
ELE16-01843 Electrical Rough-In6/9/20166/10/20166/9/2016 11:30:40 PMACANC
Phone #: ###-#### >> Inspection requested via web by Don Conley Inspection cancelled from web by: Don Conley
ELE16-01846 Electrical Rough-In6/9/20166/10/20166/9/2016 3:52:03 PMACANC
This is for underground, please call Clay with any questions ###-####. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan