Inspections for the day of: Wednesday, June 10, 2020.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02225 Final6/4/20206/10/20206/10/2020 3:38:08 PMPPASS
INSTALLER JEREMY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
MEC20-02181 Final6/4/20206/10/20206/10/2020 2:55:18 PMPPASS
Field super : Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace in attic a/c coil co locking caps ok
MEC20-02242 Final6/5/20206/10/20206/10/2020 11:23:58 AMPCANC
Cathy Maestas ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- per phone call with Mary need to reschedule minimum 14 days
MEC20-01731 Rough-in6/9/20206/10/20206/10/2020 10:56:46 AMAPART
3rd floor units 307 ; 312 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- 307 and 312 R/I ok to cover
MEC20-02140 Final6/9/20206/10/20206/10/2020 9:50:41 AMAFAIL
Final for install of new a/c and indoor coil. someone is always home, garage is unlocked as this is a family care home. Phone #: ###-#### Inspection requested via web by Dan Ricken- arma flex needs completed to coil in garage to coil enclosure- breaker installed in panel is 30 amp and max amp for condenser is 25 amps max- need locking caps on a/c service ports- recall in when corrections made
MEC20-02325 Rough-in6/9/20206/10/20206/10/2020 9:01:23 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino-
7822
1- need city approved man j onsite
2- need to firecaulk fireplace flue
3- need lineset box installed exterior of house at condenser location

7800
1- need city approved man j onsite
2- fireplace flue needs leveled off fireplace/ insulation shield needs 1" clearance around pipe/ firestop at attic needs 1" clearance to b vent to wood

left notice front window of unit 7800
MEC20-02325 Pressure Test6/10/20206/10/20206/10/2020 8:56:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino- 20lb gas pass units 7800 and 7822 ok to cover- 7800 needs underground tested when installed from meter to house
MEC20-02152 Rough-in6/9/20206/10/20206/10/2020 8:30:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC20-01971 DOC - Permit Finaled6/10/20206/10/20206/10/2020 8:01:27 AMAPASS
correction made