MEC20-02225
| Final | 6/4/2020 | 6/10/2020 | 6/10/2020 3:38:08 PM | P | PASS |
|
|
INSTALLER JEREMY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-02181
| Final | 6/4/2020 | 6/10/2020 | 6/10/2020 2:55:18 PM | P | PASS |
|
|
Field super : Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace in attic a/c coil co locking caps ok
|
MEC20-02242
| Final | 6/5/2020 | 6/10/2020 | 6/10/2020 11:23:58 AM | P | CANC |
|
|
Cathy Maestas ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- per phone call with Mary need to reschedule minimum 14 days
|
MEC20-01731
| Rough-in | 6/9/2020 | 6/10/2020 | 6/10/2020 10:56:46 AM | A | PART |
|
|
3rd floor units 307 ; 312 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- 307 and 312 R/I ok to cover
|
MEC20-02140
| Final | 6/9/2020 | 6/10/2020 | 6/10/2020 9:50:41 AM | A | FAIL |
|
|
Final for install of new a/c and indoor coil. someone is always home, garage is unlocked as this is a family care home. Phone #: ###-#### Inspection requested via web by Dan Ricken- arma flex needs completed to coil in garage to coil enclosure- breaker installed in panel is 30 amp and max amp for condenser is 25 amps max- need locking caps on a/c service ports- recall in when corrections made
|
MEC20-02325
| Rough-in | 6/9/2020 | 6/10/2020 | 6/10/2020 9:01:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino- 7822 1- need city approved man j onsite 2- need to firecaulk fireplace flue 3- need lineset box installed exterior of house at condenser location
7800 1- need city approved man j onsite 2- fireplace flue needs leveled off fireplace/ insulation shield needs 1" clearance around pipe/ firestop at attic needs 1" clearance to b vent to wood
left notice front window of unit 7800
|
MEC20-02325
| Pressure Test | 6/10/2020 | 6/10/2020 | 6/10/2020 8:56:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino- 20lb gas pass units 7800 and 7822 ok to cover- 7800 needs underground tested when installed from meter to house
|
MEC20-02152
| Rough-in | 6/9/2020 | 6/10/2020 | 6/10/2020 8:30:57 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC20-01971
| DOC - Permit Finaled | 6/10/2020 | 6/10/2020 | 6/10/2020 8:01:27 AM | A | PASS |
|
|
correction made
|