Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM02-01656 Plumbing Rough-in6/10/20026/11/20026/11/2002 12:00:00 AMAPASS
Scheduled by Inspector: 309 On 6/10/2002 1:50:09 PM
PLM02-00476 Plumbing Rough-in6/11/20026/11/20026/11/2002 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 06/11/2002 at 08:42:45. Contact: ###-####. upc 905.5 repipe upstaires shower trap so that vent opening is not below weir of trap upc 313.2 off set venl around Elc. box in powder room so piping and fitting,s are not under stress or strain upc 419 provide vent or vent,s for future fixtures in basement. need to cap 3 inch drain under stair,s in basement. called plumbing contractor and left correction notice on job site 6/11/2002 3:41:17 PM
PLM02-01695 Water and/or Sewer6/11/20026/11/20026/11/2002 12:00:00 AMPPASS
JIM ###-####
PLM02-01645 Water and/or Sewer6/11/20026/11/20026/11/2002 12:00:00 AMPPASS
pauline ###-####
PLM02-01561 Water and/or Sewer6/11/20026/11/20026/11/2002 12:00:00 AMPPASS
pauline ###-####
PLM02-01560 Water and/or Sewer6/11/20026/11/20026/11/2002 12:00:00 AMPPASS
pauline ###-#### water and sewer hook-up only 6/11/2002 4:10:06 PM
PLM02-01497 Water and/or Sewer6/11/20026/11/20026/11/2002 12:00:00 AMPFAIL
pauline ###-#### upc 708.0 need to correct reverse grade in 3 inch horizontal drain piping note permit iss. for 1288 oakwood correct address 1301 oakwood lane 6/12/2002 11:19:32 AM
PLM01-02106 Final6/10/20026/11/20026/11/2002 12:00:00 AMPPART
###-#### walk through first floor and kit area all blackflow device,s tested and certified except for r.p. in pool equip. room oked temp. 6/11/2002 6:32:28 PM