Inspections for the day of: Monday, June 11, 2007.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02081 Rough-In Permanent Service6/11/20076/11/20076/11/2007 3:41:10 PMPCANC
Scheduled by a contractor via Hello! on 6/11/2007 at 11:09:26 AM. Contact: ###-####. wrong type request, see ri
ELE07-02081 Electrical Rough-In6/11/20076/11/20076/11/2007 3:34:44 PMPPASS
Scheduled by a contractor via Hello! on 6/11/2007 at 11:09:26 AM. Contact: ###-####. ok to pour gec, ric ok
ELE07-02100 Conference6/11/20076/11/20076/11/2007 2:52:33 PMPDONE
neil; Phone #: ###-#### Note: please call 1/2 hr prior Internet Inspection Request from: Cathy Chiles talked about service requirements for duplex that will convert to townhouse, told that they need 2 services and bld's and no penetration thru other side, or they can do duplex construction and change later, but not preferred method
ELE07-00920 Final6/11/20076/11/20076/11/2007 2:07:44 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: DJ Carman called, left corr notice, nec 210.52(E) sahll install recpt at rear of dwelling, 210.52(D) shall install recpt upper bath, 110.3 fan shall operate, lower bath, 422.11(A) overcurrent for a/c shall not exceed mfgrs marking
ELE07-00918 Final6/11/20076/11/20076/11/2007 1:38:10 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: DJ Carman called, left corr notice, nec 210.52(E) shall install recpt at rear of dwelling, 406.4 recpts shall be securely fastened, 406.5 recpt faceplates shall seat against mounting surface,406.4(D) recpt face shall be flush with or project from faceplate,422.11(A) overcurrent device for a/c shall not exceed mfgr marking on nameplate, 110.3 hall recpt shall operate
ELE07-00917 Final6/11/20076/11/20076/11/2007 1:25:40 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: DJ Carman called, left corr notice, nec 210.52(E) shall install recpt at rear of dwelling, 406.4 recpts shall be securely fastened in place, 406.4(D) recpt face shall be flush with or project from faceplate, 406.5 recpt faceplates shall completely cover opening and seat against mounting surface, 422.11(A) overcurrent device for a/c shall not exceed mfgrs marking
ELE07-02032 Final6/6/20076/11/20076/11/2007 10:48:26 AMAPASS
Inspection of existing house panel in garage for final. Re-fed existing 125A panel from new 200A service. Was not finished @ time of RI-Perm to reconnect ID Power. Home owner to be home 6/11/07 am. Thank you -- Lynn ###-####. Internet Inspection Request from: Lynn Solmon called to finish panel schedule as survey, ok to final
ELE07-02005 Electrical Rough-In6/8/20076/11/20076/11/2007 10:13:13 AMAFAIL
Dave; Phone #: ###-#### Internet Inspection Request from: Hattie James called, left corr notice, nec 358.30(A) emt shall be supported within 12" of box, 330.30(B) mc cable shall be secured within 12" of box, and not over 6' in length without strapping,(whips) 300.4(A)&(D) edge of bored holes and raceways shall be 1 1/4" from edge of framing members, 300.11(A) support wires shall be provided for fixtures, BCC no violations shall be retained- no lv wiring on grid
ELE07-01846 Final6/8/20076/11/20076/11/2007 9:23:03 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Tina Payne ok to final, told contr to get lv off grid, signed occ card
ELE07-01246 Final6/7/20076/11/20076/11/2007 8:24:34 AMAPASS
Per Jim S. Gene - ###-#### journeyman Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok to final, signed card