Inspections for the day of: Wednesday, June 11, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02302 Electrical Rough-In6/10/20086/11/20086/11/2008 4:09:14 PMPPART
Contact Steve Hess. Ceiling Inspection. Phone #: ###-#### Internet Inspection Request from: Shelli Daylong
corridor ceilings E F I&J ok anop
ELE08-01228 Final6/11/20086/11/20086/11/2008 3:30:42 PMPPASS
steve Phone #: ###-#### called survey needs outlet left of door final ok card signed contr will install outlet and call me
ELE08-01448 Electrical Rough-In6/11/20086/11/20086/11/2008 3:01:24 PMPFAIL
Mike- call 20 min prior to going Phone #: ###-#### contr did not remove all the sheetrock that I told him to remove , where it was removed I found violations 300.4 11/4" for cables parallel to framing members, also NMB cables not stapled within 8" of boxes
ELE08-01459 Electrical Rough-In6/11/20086/11/20086/11/2008 1:22:46 PMPPART
George Phone #: ###-#### walls ok only shall correct violations iabove grid ceiling, open boxes box fill seal KOs remove unused jboxes and wiring layed on ceiling tiles no ESC talked with contr
ELE08-01561 Rough-In Permanent Service6/11/20086/11/20086/11/2008 12:38:10 PMPCANC
darrel - suite 104 Phone #: ###-#### no ESC attached to project p/s u/g for meter ok
ELE08-01560 Rough-In Permanent Service6/11/20086/11/20086/11/2008 12:37:21 PMPPASS
darrel Phone #: ###-#### - suite 103
no ESC attached to project p/s u/g for meter ok
ELE08-01079 Final6/10/20086/11/20086/11/2008 11:40:17 AMANR
jerod Phone #: ###-#### needs gfci for all spa equipment called
ELE08-01552 Electrical Rough-In6/11/20086/11/20086/11/2008 11:01:42 AMANH
Inspection for cover for the cieling area. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean no access called
ESC08-00499 Random Inspection6/11/20086/11/20086/11/2008 10:11:14 AMAPART
site ok card posted
ELE08-01556 Electrical Rough-In6/10/20086/11/20086/11/2008 10:10:25 AMAPART
Jason- bonding Phone #: ###-####
pool bond and lights ok only no u/g
ELE08-01513 Permanent Service6/10/20086/11/20086/11/2008 9:31:24 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Joe Thomas needs to bond around insulating joints 250.52(A)(1)
p/s o/h new rec. ok
ELE08-00342 Electrical Rough-In6/10/20086/11/20086/11/2008 8:47:58 AMAPART
Taggart Phone #: ###-#### new ethanol bay ok
ELE08-00824 ELE-Aging Inspection6/11/20086/11/20086/11/2008 8:46:50 AM DONE
wsuc
ELE08-00086 ELE-Aging Inspection6/11/20086/11/20086/11/2008 8:46:31 AM DONE
waiting for call