Inspections for the day of: Friday, June 11, 2010.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00790 ELE-Aging Inspection6/11/20106/11/20106/15/2010 3:50:36 PM CANC
ELE09-00471 ELE-Aging Inspection6/11/20106/11/20106/15/2010 3:49:58 PM CANC
ELE09-02473 ELE-Aging Inspection6/11/20106/11/20106/15/2010 3:49:49 PM CANC
ELE10-00805 Electrical Rough-In6/11/20106/11/20106/11/2010 4:05:58 PMPPASS
Cal- call for access Phone #: ###-####
ELE10-00805 Final6/11/20106/11/20106/11/2010 4:05:49 PMPPASS
Cal- call for access Phone #: ###-####
ELE10-00625 Rough-In Permanent Service6/11/20106/11/20106/11/2010 4:05:23 PMPFAIL
Jamie''s cell is ###-#### Inspection requested from web by: Jamie Winters
called stillneeds to terminate GEC at neutral (grounded) bus, not the equipment grounding bus
ELE10-00915 Electrical Rough-In6/11/20106/11/20106/11/2010 4:03:05 PMPPASS
Corey Phone #: ###-#### ceilings
ELE10-00882 Final6/11/20106/11/20106/11/2010 4:02:28 PMPPASS
Inspection requested from web by: Tracy Robertson Phone #: ###-####
ELE09-01933 Final6/10/20106/11/20106/11/2010 4:02:00 PMPPASS
Inspection requested from web by: Terry Scott Phone #: ###-####
ELE10-00739 Final6/11/20106/11/20106/11/2010 4:01:12 PMPPASS
danny Phone #: ###-#### ok card signed
ELE09-00550 Final6/10/20106/11/20106/11/2010 4:00:34 PMAPASS
Please do a final inspection on the rearranged kitchen. Lighting, outlets, dishwasher, water heater etc. The Church will be occupied between 9:00am and 4:30pm. Sorry for the delay, only received permission to finish the dishwasher last week. Inspection requested from web by: nathan palmer Phone #: ###-####ok survey posted called
ELE10-00824 Permanent Service6/11/20106/11/20106/11/2010 12:59:30 PMAFAIL
Inspection requested from web by: david bradshaw Phone #: ###-#### needs bond screw or strap equip grd bus, also bushing
ELE10-00878 Final6/11/20106/11/20106/11/2010 11:41:20 AMPPASS
Jared-Please call at least 30 mins prior for access Phone #: ###-####
ELE09-01932 Final6/10/20106/11/20106/11/2010 10:25:59 AMAPART
Final for phase 10 only. Please don''t final permit. Nick is the contact his no. is ###-#### ok
ELE10-01273 Final6/10/20106/11/20106/11/2010 10:25:03 AMAPASS
Contact: John Ostolasa Inspection requested from web by: Deb Gooden Phone #: ###-####
ELE10-01101 Electrical Rough-In6/10/20106/11/20106/11/2010 9:15:04 AMAFAIL
WIRES MOVED FOR DOORWAY Inspection requested from web by: Aaron Decker Phone #: ###-#### called stap all cables and raceways, nail plates and 11/4" , needs required sign circuit
ELE10-00739 Final6/10/20106/11/20106/11/2010 8:34:59 AMACANC
grid and final insp//Danny Phone #: ###-#### nr see added r/i
ELE10-00739 Electrical Rough-In6/11/20106/11/20106/11/2010 8:34:41 AMAPART
grid and final insp//Danny Phone #: ###-#### needs to strap cables, seperate cables, and wires for boxes
ELE09-02028 Final6/11/20106/11/20106/11/2010 7:10:48 AMAPASS
ELE09-00660 Final6/11/20106/11/20106/11/2010 7:09:46 AMAPASS
ELE09-01745 Final6/11/20106/11/20106/11/2010 7:09:04 AMAPASS
work was done on permit #ele09-02033
ELE10-01245 Final6/10/20106/11/20106/10/2010 1:46:08 PMAPASS
Please inspect Bench has been removed and the Grounding is complete. Mark is our contact ###-#### Inspection requested from web by: Clint Tate Phone #: ###-####