Inspections for the day of: Friday, June 11, 2010.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-02379 ELE-Aging Inspection6/11/20106/11/20106/17/2010 6:37:40 AM DONE
see final
ELE09-02326 ELE-Aging Inspection6/11/20106/11/20106/17/2010 6:36:23 AM DONE
suc
ELE09-01821 ELE-Aging Inspection6/11/20106/11/20106/14/2010 6:27:51 AM DONE
see final
ELE07-02464 ELE-Aging Inspection6/11/20106/11/20106/14/2010 4:53:26 AM DONE
see doc expire
ELE08-01626 ELE-Aging Inspection6/11/20106/11/20106/14/2010 4:52:06 AM DONE
suc
ELE08-01600 ELE-Aging Inspection6/11/20106/11/20106/14/2010 4:50:05 AM DONE
see doc expire
ELE07-02650 ELE-Aging Inspection6/11/20106/11/20106/11/2010 4:12:53 PM DONE
see doc expire
ELE07-02650 DOC - Permit Expired6/11/20106/11/20106/11/2010 4:12:38 PMPPASS
no activity
ELE10-01269 Electrical Rough-In6/11/20106/11/20106/11/2010 4:06:25 PMPPASS
underground Inspection requested from web by: Rick Beckman Phone #: ###-#### correcftions made, ok to cover u/g
ELE10-01279 Electrical Rough-In6/11/20106/11/20106/11/2010 3:25:28 PMPPASS
Inspection requested from web by: kendall bender Phone #: ###-#### ok to re-do lighting
ELE10-00900 Electrical Rough-In6/11/20106/11/20106/11/2010 2:13:14 PMPPASS
Ron-rough for cover inspection please Phone #: ###-#### ok to cover counters
ELE10-00900 Permanent Service6/11/20106/11/20106/11/2010 2:13:03 PMPPASS
Ron-rough for cover inspection please Phone #: ###-#### p/s, exst meter pak, n, ok, 1 meter only
ELE10-01134 Electrical Rough-In6/11/20106/11/20106/11/2010 1:30:11 PMPPASS
Underground trench inspection please-colt Phone #: ###-#### ok to cover u/g house to garage
ELE10-01173 Electrical Rough-In6/11/20106/11/20106/11/2010 12:41:33 PMPPASS
Corrections are complete. Inspection requested from web by: Steve Craig Phone #: ###-#### corrections made, baths ok to cover
GCE10-00045 GCE-Final6/10/20106/11/20106/11/2010 10:43:27 AMACANC
Scope of Inspection: FinalContact: ###-####**Located behind Car Wash** wrong type request, see ri
GCE10-00045 GCE-Rough-In6/11/20106/11/20106/11/2010 10:43:01 AMAPASS
Scope of Inspection: FinalContact: ###-####**Located behind Car Wash** ok to cover downstairs ceilings only
ELE10-00847 Electrical Rough-In6/10/20106/11/20106/11/2010 10:21:26 AMAPASS
Floor heat install in master bath and 2nd floor bath Inspection requested from web by: Therrin Robertson Phone #: ###-#### ric ok
ELE10-00803 Final6/10/20106/11/20106/11/2010 9:51:16 AMAPASS
Please Call 1/2 hour before inspection for access.
Thanks, Dan Inspection requested from web by: Dan Rohl Phone #: ###-#### ok to final
ELE10-00939 Final6/10/20106/11/20106/11/2010 9:16:11 AMAPASS
Inspection requested from web by: Therrin Robertson Phone #: ###-#### ok to final
ELE10-01275 Electrical Rough-In6/11/20106/11/20106/11/2010 8:43:19 AMAPART
please inspect conduit from house to new building site Inspection requested from web by: Shaun Kirkman Phone #: ###-#### ok to cover u/g from house to edge of new structure only, needs more conduit and grounding at structure, called, left message
ELE10-01269 Electrical Rough-In6/10/20106/11/20106/11/2010 8:07:06 AMAFAIL
underground electrical Inspection requested from web by: Rick Beckman Phone #: ###-#### called, left correction notice,NEC 310.15(B)2(b) shall maintain spacing between conduit if more than 1 conduit, NOTE: corrections shall be made within 5 working days or further action will be taken