ELE08-01583
| Rough-In Permanent Service | 6/12/2008 | 6/12/2008 | 6/12/2008 3:21:10 PM | P | FAIL |
|
|
daniel Phone #: ###-#### 210.52(A)&(C) needs out wall space MB, outlet spacing countertop left of sink in kit. , nail plates and 11/4" complete all wiring grd p/s, protect wires by attic access corr & do not cover posted called
|
ESC08-00371
| Random Inspection | 6/12/2008 | 6/12/2008 | 6/12/2008 2:32:12 PM | P | PART |
|
|
site ok
|
ELE08-01585
| Electrical Rough-In | 6/12/2008 | 6/12/2008 | 6/12/2008 2:31:13 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok
|
ELE08-01079
| Final | 6/12/2008 | 6/12/2008 | 6/12/2008 1:55:45 PM | P | PASS |
|
|
Jared Phone #: ###-#### ok
|
ESC08-00261
| Random Inspection | 6/12/2008 | 6/12/2008 | 6/12/2008 1:25:54 PM | P | PART |
|
|
site ok
|
ELE08-01181
| Electrical Rough-In | 6/12/2008 | 6/12/2008 | 6/12/2008 1:24:51 PM | P | PASS |
|
|
Mike Phone #: ###-#### ok
|
ELE08-01247
| Permanent Service | 6/12/2008 | 6/12/2008 | 6/12/2008 12:53:33 PM | P | PASS |
|
|
Al Phone #: ###-#### address grd or bond to water pipe, address sub panel and range and dryer circuits also use hub or listed meyers hub for bonding p/s o/h rec. ok
|
ELE08-00604
| Final | 6/11/2008 | 6/12/2008 | 6/12/2008 11:40:06 AM | A | PASS |
|
|
Shoe Carnival Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ok card signed
|
ESC08-00397
| Random Inspection | 6/12/2008 | 6/12/2008 | 6/12/2008 10:26:04 AM | A | PART |
|
|
site ok
|
ELE08-01372
| Electrical Rough-In | 6/12/2008 | 6/12/2008 | 6/12/2008 10:25:13 AM | P | PASS |
|
|
jeff - grid on pool Phone #: ###-#### ok
|
ELE08-01542
| Electrical Rough-In | 6/11/2008 | 6/12/2008 | 6/12/2008 9:50:33 AM | A | PART |
|
|
Added 2 additional floor outlets Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS ok
|
ELE08-01521
| Electrical Rough-In | 6/11/2008 | 6/12/2008 | 6/12/2008 9:50:12 AM | A | PASS |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten survey posted called ok
|
ELE08-01521
| Final | 6/12/2008 | 6/12/2008 | 6/12/2008 9:49:47 AM | A | PASS |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ok
|
ELE08-00950
| Electrical Rough-In | 6/12/2008 | 6/12/2008 | 6/12/2008 8:33:17 AM | P | FAIL |
|
|
Hot Tub installation. Contact is Bill Stokes. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery job not ready needs to bond all metal when installed and complete, and addressspeaker locations, and gfci recept called
|
ELE08-00950
| Final | 6/11/2008 | 6/12/2008 | 6/12/2008 8:29:53 AM | A | NR |
|
|
Hot Tub installation. If possible, please call ###-####, 45-60 minutes prior to coming to inspect. Thank you. Contact is Bill Stokes. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery see r/i
|