Inspections for the day of: Tuesday, June 12, 2018.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-02053 Final6/11/20186/12/20186/12/2018 3:50:54 PMPFAIL
Call James at ###-#### to coordinate Phone #: ###-#### Inspection requested via web by Sabrina DeHority
James wasnt schedualed to be onsite
MEC18-02054 Final6/11/20186/12/20186/12/2018 3:50:27 PMPFAIL
Call James to coordinate at ###-#### Phone #: ###-#### Inspection requested via web by Sabrina DeHority
james wasnt schedualed to be on site
MEC18-02703 Final6/11/20186/12/20186/12/2018 3:10:13 PMPCANC
PM. CHUCK ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
MEC18-02656 Final6/12/20186/12/20186/12/2018 3:03:36 PMPPASS
Please call the customer when on the way: Carol ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MIS18-00224 MEC-Final6/12/20186/12/20186/12/2018 2:58:46 PMPFAIL
Charles Madsen-call prior to meet for access Phone #: ###-####
2nd floor mechanical work needs to be permitted
MEC18-02205 Final6/11/20186/12/20186/12/2018 2:45:50 PMPFAIL
PLEASE CALL HOMEOWNER KATHY AT # LISTED AT LEAST 15 MIN B4 ARRIVE; PLEASE COME AFTER 2 P.M. AIF POSSIBLE FOR FINAL INSPECTION OF FURNACE, A/C, ; GAS LINE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
gas pressure test at zero, need flue pressure test witnessed
MEC18-01252 Final6/12/20186/12/20186/12/2018 2:25:53 PMPPASS
Phone #: ###-#### Inspection requested via web by Dave DeChambeau
MEC18-02648 Pressure Test6/12/20186/12/20186/12/2018 1:38:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC18-02648 Rough-in6/11/20186/12/20186/12/2018 1:37:51 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC17-05332 Final6/12/20186/12/20186/12/2018 1:27:11 PMPCANC
AC:6365 Phone #: ###-#### Inspection requested via web by Gary Reeves
they just poored concrete, no access
MEC18-02708 Pressure Test6/12/20186/12/20186/12/2018 1:26:37 PMPPASS
Inspection requested via web by Margie Rowe
MEC18-02708 Final6/12/20186/12/20186/12/2018 1:26:24 PMPPASS
Inspection requested via web by Margie Rowe
MEC18-02654 Final6/11/20186/12/20186/12/2018 1:00:36 PMPPASS
Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC18-02654 Pressure Test6/11/20186/12/20186/12/2018 1:00:21 PMPPASS
Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
5lb
MEC18-02474 Rough-in6/12/20186/12/20186/12/2018 12:57:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
MEC18-02474 Pressure Test6/12/20186/12/20186/12/2018 12:57:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
20lb gas 5lb flue
MEC18-02584 Pressure Test6/11/20186/12/20186/12/2018 11:30:25 AMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
need to pay fees before Reinspection
MEC18-02178 Pressure Test6/12/20186/12/20186/12/2018 11:04:22 AMPCANC
please call Tyler ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
MEC18-02178 Rough-in6/12/20186/12/20186/12/2018 11:04:18 AMPCANC
please call Tyler ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
MEC16-03630 Mec-Aging Inspection6/12/20186/12/20186/12/2018 10:29:59 AM CANC
MEC18-02701 Final6/11/20186/12/20186/12/2018 10:29:47 AMAFAIL
Heather-please call 30 minutes prior to meet Phone #: ###-####
bvent need 1" clearance where it penetrates the roof
MEC18-02305 Rough-in6/11/20186/12/20186/12/2018 10:29:47 AMAPASS
Inspection requested via web by David Petsche
MEC18-02409 Final6/11/20186/12/20186/12/2018 9:39:39 AMAPASS
Ladder is now dropped off and provided for you and will be on left side of building, closest to the green belt if facing from parking lot. Any questions or concerns, you can call me at office- Steve Dale- ###-#### Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC18-01573 Pressure Test6/11/20186/12/20186/12/2018 9:15:56 AMAFAIL
Les Phone #: ###-####
need 18gage tracer wire
MEC18-01432 Final6/12/20186/12/20186/12/2018 8:47:30 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jon VanderStelt
gas piping needs sediment trap before furnace and W/H
MEC18-01431 Final6/12/20186/12/20186/12/2018 8:46:55 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jon VanderStelt
gas piping needs sediment trap before furnace and water heater
MEC18-02584 Rough-in6/11/20186/12/20186/12/2018 8:29:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
correction not made, test at zero